Permacoat 5000
- Chemical Family
- Epoxy & Epoxy Derivatives
PERMACOAT 5000 is a 100% solids epoxy novolac floor coating. PERMACOAT 5000 can be used as a glaze coat for the PERMATEC floors, or as a two-coat flooring or containment system (30 - 80 mils). When applied as a two-coat floor or containment system, a silica broadcast is used between coats. PERMACOAT 5000 consists of two components, resin and hardener, in both the horizontal and vertical formulations. Its application is accomplished with rubber squeegees and short nap paint rollers.
Product families
Applications
- Floor Coatings
Product Families
- Top Coats
Other characteristics
- Brand
- Permacoat
- Features
Chemical Resistant; PERMACOAT 5000 allows for a fast, easy application.; It also offers chemical resistance and physical performance much higher than those found in paints and other thin mil coatings.; At 30 - 50 mils, PERMACOAT 5000 provides excellent chemical resistance for splash and spill exposures.; In addition, when applied at 50 - 60 mils, it can often be recommended for containment service.; Rapid cure resulting in minimal downtime.; Odor free; Non-skid safety finish
- Product Type
2K (2 component) Coating, Solventless & High Solids Coating; 2K (2 component) Coating; Solventless & High Solids Coating
- Application Area
- Food Processing, Pulp And Paper Mills
- Food Processing
- Pulp And Paper Mills
- Compatible Substrates & Surfaces
- Concrete, Metal, Steel, Wood
- Mixing
Prior to application of PERMACOAT 5000, the resin, hardener and substrate should be between 70°F and 95°F. Premix the Resin (Part A) for 30 seconds using a Jiffler mixer blade attached to a 500 - 750 RPM drill. Add the Hardener (Part B) only when the batch is ready to be applied. Mix for approximately 90 - 120 seconds. After mixing, pour immediately onto the floor.
- Safety
PERMACOAT 5000 contains blended epoxies as the resin and blended amines as the hardener. Protective clothing and gloves are recommended to prevent sensitization to these materials. In case of ingestion or eye contact, it is advisable to contact a physician immediately.
- Markets
- Building & Construction
- Clean Up
All mixing and application equipment should be cleaned immediately after use. If this is done, soap and water or biodegradable cleaners can be used. If the material has begun to set, more aggressive solvents will be necessary.
- Cure Time Cycle
The cure time of PERMA Coat 5000 and other resinous systems are very dependent upon the temperature of the substrate. The chart below represents the approximate times for the respective service conditions, following the last coat:
- Function
PERMACOAT 5000 is designed as a medium duty (30 - 80 mils) floor coating and/or secondary containment system where moderate mechanical abuse and chemical exposure are anticipated. PERMACOAT 5000 can be installed over most sound floors, including old or new concrete, steel and wood, providing a cost-effective alternative to high-build floor toppings.
- PACKAGING
PERMACOAT 5000 is packaged in one and three gallon units. Each unit consists of pre-measured components, Part A (Resin) and Part B (Hardener).
- Maintenance
For systems designed for splash and spill exposures, routine wash downs are recommended to reduce the length of chemical exposure. This step is not necessary where the product is recommended for containment service.
- Technology
- Ready-to-Use Products
Technical data
Table 1 of 1
7 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Solids (Volume) | 100.0 | % | — |
| Compressive Strength | 15000.0 | psi | ASTM C579 |
| Flexural Strength | 17000.0 | psi | ASTM D790 |
| Tensile Strength | 11000.0 | psi | ASTM D307 |
| Hardness | 82 - 85 | Shore D | ASTM D2240 |
| Taber Abrasion (CS 17 Wheels, Loss/1000 Cycles) | 25.0 | mg | ASTM D4060 |
| Bond Strength to Concrete | Exceeds Tensile Stregth of Concrete | — | ASTM D4541 |