Wohl Coatings BB-99 Bituminous Black Pipe Coating
BB-99 Bituminous Black Pipe Coating is a tough, durable coating for lasting protection of steel pipe. The pipe coating is effective for both indoor and outdoor storage. It can be applied to new and reconditioned pipe. When applied over light rust it will stop further deterioration. For shop application only. Not for architectural use.
Product families
- Protective Coatings
Other characteristics
- Features
Durable, High Gloss, Improved Toughness, Outdoor Durability
- Product Type
- Coating
- Application Area
- Pipes
- Application Method
- Brush, Roller, Spray
- Compatible Substrates & Surfaces
- Concrete, Galvanized Steel, Metal, Steel, Wood
- Markets
- Building & Construction
- Paints & Coatings
- PACKAGING
- 400 lbs / 60 lbs
- Resistance
BB-99 is designed for exposures to mild chemical fumes under typical atmospheric conditions.
- Shelf LIfe
- 3 years when stored inside at 40°F to 110°F
- Technology
- Ready-to-Use Products
- Typical Uses
Excellent exterior durability and adhesion over most metal, wood, and concrete surfaces.
- Primer/Substrates
BB-99 Pipe Coating may be applied directly to properly prepared steel substrates and weathered galvanized steel.
- Application Methods
- Brush
- Roller
- Spray
- Ready to Use Product Features
- Durable
- High Gloss
- Improved Toughness
- Outdoor Durability
- Compatible Substrates and Surfaces
- Concrete
- Galvanized Steel
- Metal
- Steel
- Wood
Technical data
Table 1 of 2
9 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Pencil Hardness (Ambient Cure) | Soft to 4B | — | — |
| Adhesion | 300.0 | psi | ASTM D 4541 |
| Temperature Resistance (Non-immersion, Continuous) | 250.0 | °F | — |
| Temperature Resistance (Non-immersion, Non-continuous) | 300.0 | °F | — |
| Theoretical Solids (Volume, Mixed Material) | 34 - 36 | % | — |
| Theoretical Coverage (Mixed Gallon, 1 mil) | 560.0 | sq. ft. | — |
| Volatile Organic Content (Unthinned Ready to Apply) | 5.03 | lbs./gal. | — |
| Theoretical Coverage (1 mils DFT) | 560.0 | sq. ft. | — |
| Theoretical Coverage (2 mils DFT) | 330.0 | sq. ft. | — |
Table 2 of 2
3 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Dry Film Thickness | 1.0 - 2.0 | mils/coat | — |
| Wet Film Thickness | 3 - 5 | mils/coat | — |
| Flash Point | 45.0 | °F | Setaflash |