To catalogue

MiraFlor WB

Chemical Family
Polyurethanes (PU)

MiraFlor WB is a two-component, 40% solids, water-based self-priming epoxy coating designed for use in multiple types of flooring applications. It can be installed neat for thin film flooring applications or with the addition of synthetic aggregate for improved slip resistance.

Product families

Applications

Building & Construction — Flooring & Surfaces
  • Other Flooring & Surface Applications

Product Families

Ready-to-Use Products — Paints & Coatings
  • Primers & Sealers

Other characteristics

Brand
MiraFlor
Features

Chemical Resistant, Cleanable, Crosslinkable, Excellent Traction, Good Color Stability, Good Surface Appearance, Good UV Stability, High Gloss, Satin Finish

Product Type

1K (1 component) Coating, Sealer, Waterborne Coating; 1K (1 component) Coating; Sealer; Waterborne Coating

Usage

Thin film interior coating applications.; Garage floors.; Showroom and restaurant floors.; Light and moderate manufacturing/warehouse facilities.; Transportation terminals.; Restrooms and cafeterias.; Hospitals and healthcare facilities.; Commercial and institutional facilities.; Stadiums and arenas.; Decorative flooring treatments.

Markets
Building & Construction
Mix Ratio
Comp. A to Comp. B = 1:1 by volume.
Limitations

Intended for use by professional installers only.; Not intended for use in exterior environments due to potential for yellowing from UV exposure.; Minimum ambient/substrate temperature of 50°F (10°C) required.; Concrete must be minimum age of 7 days, depending on curing and drying conditions.; Color may yellow over time when exposed to UV.; Maximum allowable moisture vapor transmission (MVT) of 10.0 lbs./1000 sf./per 24 hr. period per ASTM F1869 (CaCl Testing).; Maximum allowable moisture vapor transmission (MVT) of 84% RH as per ASTM F2170 (RH-Relative Humidity Testing).; Use MiraPrime MVERS Plus epoxy moisture mitigation primer over concrete substrates that have MVT emissions that exceed these limits.

Technology
Ready-to-Use Products
For Best Results

Always install a minimum 4' by 4' test area site mock-up for approval of acceptable color, texture, finish, adhesion, and any other critical requirement acceptable to the owner prior to proceeding with the installation.; Verify and download current versions of product technical data sheets (PTDS), material safety data sheets (MSDS), and installation guides (IG).; Protect materials at all times from excessive heat and cold, and pre-condition to room temperature, as necessary.; Regularly check wet film thickness with mil gage and monitor consumption to ensure correct application rates are obtained.; The proper application of this product is the sole responsibility of the end user. Job site visits by Miracote representatives are only for the purpose of making recommendations, and do not assume any liability for supervision or quality control.; Measure ambient and surface temperatures to ensure the material is only applied between a minimum of 50° F and a maximum of 90° F during placement and cure time.; Consider the use of MiraPrime Aqua-Blok XL to pretreat concrete floor slabs to mitigate the potential for the migration of efflorescence and development of osmotic pressure.; Always apply a minimum of two coats each at 6-8 WFT.

Technical data

Table 1 of 1

10 rows
CharacteristicValueUnitMethod
Viscosity1,100 -1,200cps—
Weight Solids (mixed)40.0%—
Volume Solids (mixed)42.0%—
Pot Lifeapprox. 45 - 60minutes—
Dry Time (Tack free)4.0hours—
Light Traffic2022-04-06hour—
Recoat Time6 - 24hours—
Adhesion (100% Cohesive failure in concrete)min. 400psiASTM D4541
VOCmax. 5g/LEPA Method 24
Abrasion Resistance (CS 17 wheel, 1000 gram load, 1000 cycles)60.0mgASTM D4060

The Omnichem website uses cookies. By continuing to use the site, you consent to their use in accordance with our Privacy Policy and to the collection of analytics.