To catalogue

Novolak VEGlaze 472

Novolak VEGlaze 472 is a coating used for the chemical-resistant construction of sumps, ducts, containment areas, trenches, walls, and other support columns or bases. VEGlaze may be used as a thin barrier of corrosion resistance or as a topcoat for other Sauereisen vinyl ester linings and polymer concretes. The VEGlaze system utilizes Sauereisen VEPrime No. 550 as a bond enhancing primer.

Identification

Other characteristics

Brand
Novolak
Features

Chemical Resistant, Corrosion Resistant, High Temperature Resistance, Low Porosity

Product Type
  • 2K (2 component) Coating, Top Coat
  • 2K (2 component) Coating
  • Top Coat
Application Method
Gun, Roller, Spray
Compatible Substrates & Surfaces
Concrete, Metal, Steel
Markets
  • Industrial
  • Paints & Coatings
Clean Up

All equipment should be cleaned by scrubbing with a stiff brush and MEK or MCT (monochlorotoluene) at the end of each working period or when build-up becomes pronounced.

Shelf LIfe

Sauereisen VEGlaze No. 472 has a shelf life of three (3) months, when stored in unopened, tightly sealed containers in a dry location at 70°F. Avoid freezing. If there is a doubt as to the quality of the materials, consult a Sauereisen representative.

Application

VEPrime No. 550 and NovolaK VEGlaze No. 472 are each packaged in premeasured containers consisting of Hardener Part A and Resin Part B which must be mixed together before use. Individual components should be remixed before combining. The following procedures are applicable to the mixing of both products.; Completely empty contents of Hardener Part A into Resin Part B container. Using a slow-speed drill motor with a "Jiffy" type blade, mix for a minimum of three minutes until thoroughly blended.; Mix only complete batches. Material which has begun to set must be discarded. Do not try to retemper the material.

Cure
Heat Cure

Technical data

Table 1 of 1

10 rows
CharacteristicValueUnitMethod
Application Time (Working Time, 70°F)30.0minutes—
Application Time (Initial Set, 70°F)2.0hours—
Bond Strength to ConcreteConcrete Failure—ASTM D-4541
Components2 parts——
Maximum Service Temperature (Continuous exposure)350.0°F—
Maximum Service Temperature (Intermittent or Flue Gas Exposure)400.0°F—
Thickness (Wet)10.0mils—
Thickness (Dry)7.0mils—
VOC Content430.0g/LEPA Method 24
Volume Solids60.7%—

The Omnichem website uses cookies. By continuing to use the site, you consent to their use in accordance with our Privacy Policy and to the collection of analytics.