To catalogue

Creative Materials 126-22

126-22 is a pre-catalyzed, solvent-resistant, anisotropic conductive adhesive. This product features excellent adhesion to Kapton, Mylar, glass, and a variety of other substrates. Unlike conventional conductive materials, this product is very resistant to methyl ethyl ketone. This product features a hydrophobic resin that has proven well in humid aging studies and is also very resistant to scratching and creasing. Applications for 126-22 include, but are not limited to, conductive splicing of ribbon cables, PTF circuits attachments, and LED surface bonding demands. This product is useful in application where ensuring good electrical contact for all connections is a concern.\nFeatures

Properties

Physical Form
Paste

Identification

Product families

Ready-to-Use Products — Adhesives & Sealants
  • Conductive Adhesives

Other characteristics

Product Type
Conductive Adhesive
Application Area
  • Electrical Components, Ribbon Cables
  • Electrical Components
  • Ribbon Cables
Application Method
Screen Coating
Compatible Substrates & Surfaces
Glass, Plastics, Polyimide
Storage

Upon receipt of shipment, syringes should be unpacked immediately and stored in freezer at -10° C. Do not store syringes in deep freeze (-40°C).; Do not handle syringes from the body of the packaging. Handle from the ends of the packaging.; Store syringes vertically (upright) with tip side down. Do not store syringes horizontally (sideways).; Syringes should be stored in this manner until needed for production. Shelf life of syringes will be indicated on the products technical data sheet.; Syringes are labeled with product number, lot number, and manufacturing date. It is important that the syringes are used according to earliest manufacturing date, "FIFO" (first in, first out).

Shelf LIfe
2 months at 25°C
Technology
Ready-to-Use Products
Cure Schedule

Not recommended for applications that cannot cure above 110°C.

Safety and Handling

Use with adequate ventilation.; Keep away from sparks and open flames.; Avoid prolonged contact with skin and breathing of vapors.; Wash with soap and water to remove from skin.

Application Methods
Screen Coating
Preparing Syringes For Use

To thaw syringes, remove them from the freezer taking care not to handle the body of the syringe (handle from the top and/or the tip) and allow them to acclimate to ambient temperature with the tip down.; Do not use hands to warm syringe.; The thawing time for each syringe will vary based on mass and composition but a minimum of 45 minutes for 3cc, 5cc, and 10cc and a minimum of 90 minutes for 30cc syringes should be observed.; Using a heat source to thaw syringes is not advised.; Proximity to a heat source during thawing should be greater than 3 feet.; Although most materials can be refrozen minimizing freeze-thaw cycles is recommended.; Once material is fully thawed remove protective wrapping.

Certifications and Compliance
ISO 9001
Ready to Use Product Features
  • Anisotropic
  • Creasing Resistance
  • Electrically Conductive
  • Good Scratch Resistance
  • Solvent Resistant
Compatible Substrates and Surfaces
  • Glass
  • Plastics
  • Polyimide

Technical data

Table 1 of 2

1 row
CharacteristicValueUnit
Minimum Cure Temperature110°C

Table 2 of 2

5 rows
CharacteristicValueUnit
Volume Resistivity (X and Y Axis)1x10^12Ω - cm
Volume Resistivity (Z Axis)0.0001Ω - cm
Hydrolytic StabilityExcellent—
Useful Temperature Range-55 to 200ºC
Thermal StabilityGood to 250°C