Creative Materials 122-39(SD)
- Chemical Family
- Epoxy & Epoxy Derivatives
122-39(SD) is a syringe dispensable, thermally conductive, electrically insulating, one component, 100% solids epoxy adhesive. This system features excellent thermal stability, outstanding chemical resistance and excellent high temperature properties. Applications include adhesion to gold plated substrates and tin/lead solder terminated components, die attach and thermal management operations, printed circuit board fabrication, advanced material composites, sealing and high performance coatings. 122-39(SD) is a thermally conductive version of 122- 38(SD).\nFeatures\nIonically clean die attach adhesive
Product families
Applications
- Printed Circuit Boards (PCBs)
Product Families
- Conductive Adhesives
Other characteristics
- Product Type
1K (1 component) Adhesive, Conductive Adhesive, Epoxy Adhesive, Solvent free (100% Solids) Adhesive; 1K (1 component) Adhesive; Conductive Adhesive; Epoxy Adhesive; Solvent free (100% Solids) Adhesive
- Application Method
- Injection
- Markets
- Electrical & Electronics
- Storage
Upon receipt of shipment, syringes should be unpacked immediately and stored in freezer at -10° C. Do not store syringes in deep freeze (-40"C).; Do not handle syringes from the body of the packaging. Handle from the ends of the packaging.; Store syringes vertically (upright) with tip side down. Do not store syringes horizontally (sideways).; Syringes should be stored in this manner until needed for production. Shelf life of syringes will be indicated on the products technical data sheet.; Syringes are labeled with product number, lot number, and manufacturing date. It is important that the syringes are used according to earliest manufacturing date, "FIFO" (first in, first out).
- Shelf LIfe
12 months at -40°C, 6 months at -10°C, max. 4 days at 25°C
- Technology
- Ready-to-Use Products
- Safety and Handling
Use with adequate ventilation.; Keep away from sparks and open flames.; Avoid prolonged contact with skin and breathing of vapors.; Wash with soap and water to remove from skin.
- Application Methods
- Injection
- Preparing Syringes For Use
To thaw syringes, remove them from the freezer taking care not to handle the body of the syringe (handle from the top andlor the tip) and allow them to acclimate to ambient temperature with the tip down.; Do not use hands to wam syringe.; The thawing time for each syringe will vary based on mass and composition but a minimum of 45 minutes for 3cc, 5cc, and 10cc and a minimum of 90 minutes for 30cc syringes should be observed.; Using a heat source to thaw syringes is not advised.; Proximity to a heat source during thawing should be greater than 3 feet.; Although most materials can be refrozen minimizing freeze-thaw cycles is recommended.; Once material is fully thawed remove protective wrapping.
- Certifications and Compliance
- ISO 9001
- Suggested Handling and Curing
Material is ready to use as received. Store frozen to maintain consistent flow properties. Allow material to warm up to room temperature before opening container. Prior to using, mix container well to re-suspend filler if packaged in containers. Cure for 60 minutes at 150°C, or for 30 minutes at 175°C.
- Ready to Use Product Features
- Chemical Resistant
- Electrically Insulating
- Good Coating Performance
- Good Thermal Stability
- High Modulus
- High Temperature Performance
- Thermally Conductive
Technical data
Table 1 of 1
22 rows| Characteristic | Value | Unit |
|---|---|---|
| Pot Life | Latent | — |
| Conductivity | 2.1 | W/mK |
| Viscosity | 40000 | cps |
| Thixotropic Index | min. 2.5 | — |
| Filler | Aluminum Nitride | — |
| Percent Filler | 60 | — |
| Volume Resistivity | max. 1X 10^16 | Q-cm |
| Thermal Conductivity | 3.5 | W/m-K |
| Dielectric Constant (1KHz) | 4.1 | — |
| Dielectric Constant (1MHz) | 3.9 | — |
| Dissipation Factor (1KHz) | 0.027 | — |
| Dissipation Factor (1MHz) | 0.038 | — |