Oil-Stop™ Primer
- Chemical Family
- Epoxy & Epoxy Derivatives
Oil-Stop™ Primer is a two-component, solvent-based epoxy coating for coating petroleum-based ND oil-contaminated concrete. This product penetrates the substrate for excellent adhesion and is an ideal primer for the oil-contaminated concrete substrate. Recommended for petroleum oil contaminated substrates. This product is not intended for use over vegetable oil, animal fat or synthetic oil contaminated concrete. This product can withstand exposure to many common solvents and chemicals.
Product families
Applications
- Primers & Lacquers
Product Families
- Primers & Sealers
Other characteristics
- Brand
- Oil-Stop
- Features
- Good Adhesion
- Product Type
2K (2 component) Coating, Primer, Solventborne Coating; 2K (2 component) Coating; Primer; Solventborne Coating
- Compatible Substrates & Surfaces
- Concrete
- Color
- Black
- Markets
- Printing & Packaging
- Shelf LIfe
- 1 year
- Finish Coat
- Satin gloss (40-60 @ 60°C, Erichsen glossmeter)
- Flexibility
- No cracks on 1/8" mandrel
- Precaution
Use with adequate ventilation.; Avoid contact with eyes, skin and clothing, wear gloves or protective creams - if skin contact occurs, wash at the first opportunity with soap and water.; Eye exposure or inhalation can result in serious medical problems - in the event of eye contact, immediately flush eyes with water and contact a physician.; Keep out of the reach of children.; For industrial use only.
- Restrictions
Restrict use of the floor to light traffic and non-harsh chemicals until the coating is fully cured.. It is best to let the floor remain dry for the full cure cycle.
- Technology
- Ready-to-Use Products
- Floor Cleaning
Some cleaners may affect the color of the floor installed.; Test each cleaner in a small area, utilizing your cleaning technique.; If no ill effects are noted, continue to clean with the product and process as tested.
- Product Mixing
This product has a 1:1 mix ratio by volume.; After the two parts are combined, mix well with slow-speed mixing equipment such as a jiffy mixer until streak-free.; Improper mixing may result in product failure.
- Abrasion Resistance
Taber abraser CS-17 with 1,000 gram total load and 500 cycles = 37.0 mg loss
- Application
We recommend due to the vastly varying contamination parameters, it is recommended that the applicator check both the adhesion of this product to the substrate as well as a thorough evaluation of the proposed intermediate and topcoat selections.; Petroleum-based oils have a tendency to migrate upward through newly placed coatings and could cause disbonding if preceding coats are not inspected prior to top coating.; Clean all previous coatings as necessary.; This coating should not be used until a sample has been evaluated for suitability and adequate adhesion.; Make certain that the floor and air temperatures are between 55°F and 90°F (15.5°C and 32.2°C).; Preferably, the relative humidity should be below 90%.; This product should be applied by roller or brush at 5 - 8 mil thickness when wet.
Technical data
Table 1 of 3
2 rows| Characteristic | Value | Unit |
|---|---|---|
| VOC (Per Gal.) | 2.5 | lbs. |
| Mix Ratio by Volume | 1.0 | — |
Table 2 of 3
2 rows| Characteristic | Value | Unit |
|---|---|---|
| VOC (Per Gal.) | 2.75 | lbs. |
| Mix Ratio by Volume | 1.0 | — |
Table 3 of 3
9 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Clean Up | Use Xylol | — | — |
| Solids by Weight (Mixed) | 69.5 - 73.5 | % | — |
| Solids by Volume (Mixed) | 61 - 65 | % | — |
| Coverage Rate (Kit, 5 - 8 Mils Wet) | 200 - 320 | sq. ft. | — |
| Film Thickness (Per Coat Wet) | 5 - 8 | mils | — |
| Film Thickness (Dry) | 3 - 5 | mils | — |
| Viscosity (Mixed, Typical) | 150 - 300 | cps | — |
| Impact Resistance (Direct, Passed) | 50.0 | in. lb. | Gardner Impact |
| VOC | max. 310 | g/l | — |