Westcoat EC-12 Epoxy Primer
- Chemical Family
- Epoxy & Epoxy Derivatives
Westcoat EC-12 Epoxy Primer is a two-component, 100% solids, low viscosity, moisture tolerant, fast drying, high strength and multi-purpose epoxy primer.
Other characteristics
- Features
Chemical Resistant, Excellent Substrate Adhesion, Fast Drying, High Build, High Solids Content, High Strength, Low Viscosity, Moisture Resistant
- Product Type
2K (2 component) Coating, Primer, Solventless & High Solids Coating
- Application Area
- Floor
- Application Method
- Brush, Roller, Trowel, Wipe
- Compatible Substrates & Surfaces
- Coated Surfaces, Concrete, Metal, Wood
- Usage
EC-12 is used to prime concrete, metal and wood, as well as many other existing coatings. It is an allaround concrete primer/sealer.
- Color
- Black
- Blue
- Green
- Grey
- Red
- Tan
- Transparent
- White
- Mixing
Premix each component separately.; For color consistency, box all part A's. In a clean bucket, mix 2 parts A with 1 part B (by volume) of EC-12.; Mix thoroughly with a low speed (400-600 rpm) drill motor for 3-4 minutes.; Make sure to scrape the sides and bottom of the container during mixing.; After mixing is completed, remove material from container within 5 minutes, as epoxy will begin to generate heat.; Spread immediately onto the floor.; As product is spread out, you will have longer working time (10-15 minutes at 70°F).
- Markets
- Building & Construction
- Clean Up
Uncured material should be removed with an environmentally-safe solvent.; Cured material should be removed mechanically.
- Coverage
EC-12 covers up to 300 square feet per gallon under normal conditions, which will achieve 5.2 dry mils.. EC-12 may be applied at a heavier rate to achieve a higher build system or to accommodate the broadcasting of aggregates.
- Dry Time
You may re-coat as soon as the surface is dry to touch or in about 4-8 hours (but not later than 24 hours).; Light foot traffic may be permitted in 8-10 hours, light vehicle traffic in 48 hours, heavy traffic in 3 days.; All times are based on average temperature of 70 degrees F and 50% humidity.; Cooler temperatures will increase drying time.
- Moisture
All concrete should be tested for moisture before applying a seamless coating.. If moisture emissions exceed 5 lbs/1000 square feet/24 hours (ASTM F1869) or if the relative humidity (RH) exceeds 75% (ASTM F2170), contact the manufacturer before application.
- Pot Life
- 32 minutes (Gel Time, 150gm, 72°F)
- Thinning
Thin EC-12 with 1 to 2 quarts of CA-23 or acetone or in some cases, EC-12 may be thinned up to equal parts with CA-23 or acetone.; Thinned material must be applied at less than 5 mils to cure properly.; Do not allow material to puddle.
- PACKAGING
- 1.5 gal & 15 gal kits available.
- Advantages
- USDA/FDA Compliant
- 100% Solids
- Low Viscosity
- Chemical Resistant
- High Build
- Convenient 2:1 Mix
- High Strength
- Superior Adhesion
- Inspection
The surface must be structurally sound, clean, dry and free of grease, paint, oil, dust, curing agents, laitance or any foreign material that will prevent proper adhesion.; The concrete should be at least 2,500 PSI and porous or rough enough to allow the product to soak in.; A minimum of 28 days curing time is required on all concrete.; Prior to starting work, test existing concrete slab for efflorescence, moisture and hydrostatic pressure.
- Shelf LIfe
- 2 years in unopened packaging
Technical data
Table 1 of 2
7 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Color | 3.0 | — | Gardner |
| Gloss (60Degrees) | 118.0 | — | — |
| Solids By Volume (Mix) | 100.0 | % | — |
| Solids By Weight (Mix) | 100.0 | % | — |
| Viscosity (Mix) | 800.0 | cPs | — |
| Viscosity (Mix) | 65.0 | KU | — |
| Weight Per Gallon (Mix) | 9.0 | — | — |
Table 2 of 2
20 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Adhesion on Concrete | 5.0 | — | ASTM D3359 |
| Adhesion on Steel | 5.0 | — | ASTM D3359 |
| Compressive Modulus | 37300.0 | psi | ASTM D695 |
| Compressive Strength | 10100.0 | psi | ASTM D695 |
| Flexural Strength | 11135.0 | psi | ASTM D790 |
| Foot Traffic (Over Concrete, 72°F) | 7.5 | hours | — |
| Foot Traffic (Sealed Surface, 72°F) | 8.75 | hours | — |
| Hardness | 80.0 | Shore D | ASTM D2240 |
| Heat Resistance (Constant) | 130.0 | °F | — |
| Heat Resistance (Intermittent) | 180.0 | °F | — |
| Impact Resistance (Direct) | 15.0 | in-lbs | — |
| Impact Resistance (Reverse) | 2.0 | in-lbs | — |