Alcom® TCD PA66 5050 14016
- Chemical Family
- Polyamides
MOCOM Compounds Alcom® TCD PA66 5050 14016 is a thermal conductive and electrically insulating polyamide 66 material that is heat stabilized. It is used in a variety of market segments including automotive, machinery, electrical and electronic, and lighting. Typical applications include radiator systems, cooling systems, housings, functional components, plugs/connectors, and lamp sockets.
Product families
Applications
- Automotive Lighting
- Cooling & Climate
- Equipment & Parts
- Connectors
- Housings & Enclosures
- Terminal Blocks Plugs & Sockets
Product Families
- Polyamides
Other characteristics
- Brand
- ALCOM
- Polymer Name
- Polyamide 66 (PA 66)
- Fillers Included
- Proprietary
- Flexural Modulus
- 10500.0 - 10500.0 MPa
- Additives Included
- Heat Stabilizer
- Processing Methods
- Injection Molding
- Markets
- Automotive & Transportation
- Electrical & Electronics
- Industrial
- Flame Rating
- UL 94 HB
- Technology
- Plastics
- Labeling Claims
- Azo Colorants-free
- Azo Dyes-free
- Conflict minerals-free
- PAH-free
- PFOA-free
- PFOS-free
- Persistent Organic Pollutants (POP)-free
- Material Features
- Electrically Insulating
- Good Thermal Conductivity
- Heat Stabilized
- Low Anisotropy
- Thermally Conductive
- Storage Condition
- Store in dry, protected from light.
- Pre-Drying Conditions
- 80 °C in a dry air (dessiccant) dryer for 2-12 h
- Certifications and Compliance
Directive 2011/65/EC amended through EU/2015/863 (RoHS); EC No.1907/2006; IATF 16949; ISO 13485; ISO 14001; ISO 17025; ISO 45001; ISO 50001; ISO 9001; REACH (Europe); REACH (UK); RoHS Compliant; SVHC Compliant; UL 94
- Plastics and Elastomers End Uses
- Automotive Applications
- Connectors
- Cooling System
- Electrical/Electronic Applications
- Housings
- Lamp Sockets
- Machine/Mechanical Parts
- Plugs
- Plastics and Elastomers Functions
- Resin
- Plastics and Elastomers Processing Methods
- Injection Molding
Technical data
Table 1 of 8
9 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Flexural Modulus (Dry) | 10500.0 | MPa | ISO 178 |
| Flexural Strength (Dry) | 110.0 | MPa | ISO 178 |
| Tensile Modulus (Dry) | 9800.0 | MPa | ISO 527 |
| Tensile Strength at Break (Dry) | 65.0 | MPa | ISO 527 |
| Tensile Elongation at Break (Dry) | 1.0 | % | ISO 527 |
| Impact Strength (Dry, Charpy, at 23°C) | 15.0 | kJ/m² | ISO 179/1eU |
| Impact Strength (Dry, Charpy, at -40°C) | 12.0 | kJ/m² | ISO 179/1eU |
| Notched Impact Strength (Dry, Charpy, at 23°C) | 2.0 | kJ/m² | ISO 179/1eA |
| Notched Impact (Dry, Charpy, at -40°C) | 2.0 | kJ/m² | ISO 179/1eA |
Table 2 of 8
1 row| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Density (Dry) | 1510.0 | kg/m³ | ISO 1183 |
Table 3 of 8
1 row| Characteristic | Value | Unit |
|---|---|---|
| Moisture Content | max. 0.12 | % |
Table 4 of 8
6 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| HDT / A (Dry, 1.8 MPa) | 230.0 | °C | ISO 75-1/-2 |
| DSC (Melt Point, Dry) | 263.0 | °C | ISO 11357 |
| Thermal Conductivity (integral) | 2.3 | W/(m K) | ISO 22007-2 |
| Specific Heat Capacity | 1.6 | J/gK | — |
| Thermal Conductivity (in-plane) | 5.0 | W/(m K) | ASTM E 1461 |
| Thermal Conductivity (through-plane) | 1.5 | W/(m K) | ASTM E 1461 |
Table 5 of 8
3 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Dielectric Strength (Dry) | 54.0 | kV/mm | IEC 60243-1 |
| Surface Resistance | 1 x 10¹² | Ohm | DIN EN 62631-3-2 |
| Tracking Resistance (CTI, Dry) | 600.0 | — | IEC 60112 |
Table 6 of 8
1 row| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Flammability (Dry, 1.5 mm) | HB | class | UL 94 |
Table 7 of 8
2 rows| Characteristic | Value | Unit |
|---|---|---|
| Melt Temperature | 300 - 320 | °C |
| Mould Temperature | 100 - 120 | °C |
Table 8 of 8
2 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Shrinkage (Lateral, 24h) | 0.5 - 0.7 | % | ISO 294-4 |