ForTii® MX15HR
ForTii® MX15HR is a breakthrough high-temperature polyamide that offers halogen-free and halogen-containing flame retardant grades, making it suitable for demanding applications in industries such as electronics, lighting, automotive, white goods, industrial, and aerospace. It exhibits enhanced hydrolytic stability, making it resistant to aggressive coolants (water or glycol) used in engine thermal management systems. The material provides excellent mechanical performance and weld-line resistance. The processing technology for this product is injection molding, and it offers the special features of being 35% glass-reinforced and electro-friendly, specifically designed for automotive applications.
Product families
Applications
- Cooling & Climate
- Interior
Product Families
- Polyamides
Other characteristics
- Brand
- ForTii®
- Polymer Name
- Polyphthalamide (PPA)
- Fillers Included
- Glass Fiber
- Flexural Modulus
- 12000.0 - 12000.0 MPa
- Processing Methods
- Injection Molding
- Markets
- Automotive & Transportation
- Flame Rating
- UL 94 HB
- Key Features
Material characteristics: GF35, TG 1450C Key features: Best-in-class PPA for water/glycol resistance
- Technology
- Plastics
- OEM Standards
- General Motors
- Renault
- Packaging Type
- Bags
- Boxes
- Silos
- Super Sacks
- Material Features
- Chemical Resistant
- Creep Resistant
- Excellent Balance of Strength
- Heat Resistance
- High Ductility
- High Impact Resistance
- Hydrolysis Resistant
- UL Flame Rated
- OEM Specifications
- GM GMW15702-110067-PA4T GF 35
- RENAULT PMR
- Certifications and Compliance
- ISO 14001
- OHSAS
- REACH (Europe)
- UL 94
- Plastics and Elastomers End Uses
- Automotive Propulsion Cooling
- Connectors
- Cooling Hoses
- Radiator
- Thermal Management
- Plastics and Elastomers Functions
- Resin
- Plastics and Elastomers Processing Methods
- Injection Molding
Technical data
Table 1 of 6
57 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Tensile Modulus | 12500 / 12900 | MPa | ISO 527-1/-2 |
| Tensile Modulus (-40°C) | 12500 / - | MPa | ISO 527-1/-2 |
| Tensile Modulus (40°C) | 12200 / - | MPa | ISO 527-1/-2 |
| Tensile Modulus (80°C) | 11900 / - | MPa | ISO 527-1/-2 |
| Tensile Modulus (100°C) | 11600 / 5000 | MPa | ISO 527-1/-2 |
| Tensile Modulus (120°C) | 11200 / 4600 | MPa | ISO 527-1/-2 |
| Tensile Modulus (150°C) | 5300 / * | MPa | ISO 527-1/-2 |
| Tensile Modulus (160°C) | 4600 / * | MPa | ISO 527-1/-2 |
| Tensile Modulus (180°C) | 4000 / * | MPa | ISO 527-1/-2 |
| Tensile Modulus (200°C) | 3700 / * | MPa | ISO 527-1/-2 |
| Tensile Modulus (210°C) | 3500 / * | MPa | ISO 527-1/-2 |
| Tensile Modulus (Low Thickness, 1mm) | 12000 / - | MPa | ISO 527-1/-2 |
Table 2 of 6
11 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Melting Temperature (10°C/min) | 330 / * | °C | ISO 11357-1/-3 |
| Glass Transition Temperature from DMTA (tan d) | 145 / * | °C | ASTM D5026/D7028 |
| Temperature of Deflection Under Load (1.80 MPa) | 300 / * | °C | ISO 75-1/-2 |
| Temperature of Deflection Under Load (0.45 MPa) | 315 / * | °C | ISO 75-1/-2 |
| Coefficient of Linear Thermal Expansion (parallel) | 0.16 / * | E-4/°C | ISO 11359-1/-2 |
| Coefficient of Linear Thermal Expansion (normal) | 0.51 / * | E-4/°C | ISO 11359-1/-2 |
| Burning Behaviour (at 3 / * mm Nominal Thickness) | UL HB / * | class | IEC 60695-11-10 |
| Thermal Index (2500 hrs) | 183 / * | °C | IEC 60216/ISO 527-1/-2 |
| Thermal Index (5000 hrs) | 170 / * | °C | IEC 60216/ISO 527-1/-2 |
| Thermal Index (10000 hrs) | 158 / * | °C | IEC 60216/ISO 527-1/-2 |
| Thermal Index (20000 hrs) | 146 / * | °C | IEC 60216/ISO 527-1/-2 |
Table 3 of 6
4 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Volume Resistivity | >1E13 / >1E13 | Ohm*m | IEC 62631-3-1 |
| Surface Resistivity | - / >1E15 | Ohm | IEC 62631-3-2 |
| Electric Strength | 35 / 35 | kV/mm | IEC 60243-1 |
| Comparative Tracking Index | 600 / - | V | IEC 60112 |
Table 4 of 6
3 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Water Absorption | 4.1 / * | % | Sim. to ISO 62 |
| Humidity Absorption | 2 / * | % | Sim. to ISO 62 |
| Density | 1490 / - | kg/m³ | ISO 1183 |
Table 5 of 6
3 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Molding Shrinkage (parallel) | 0.35 / * | % | ISO 294-4 |
| Molding Shrinkage (normal) | 1.05 / * | % | ISO 294-4 |
| Spiral Flow Length 1.0 mm 1000 bar | 55 / * | mm | — |
Химическая стойкость
384 rows| Characteristic | Value | Unit |
|---|---|---|
| Other | Acetaldehyde (40% by mass) at 23°C | limited resistant, tests necessary to verify |
| Other | Acetamide (50% by mass) at 23°C | limited resistant, tests necessary to verify |
| Other | Acetamide (50% by mass) at >140°C | not resistant |
| Other | Acetic acid (10% by mass) at 100°C | not resistant |
| Other | Acetic acid (10% by mass) at 23°C | limited resistant, tests necessary to verify |
| Other | Acetic acid (95% by mass) at 23°C | not resistant |
| Other | Acetic anhydride | limited resistant, tests necessary to verify |
| Ketones | Acetone at 23°C | resistant |
| Other | Acetonitrile | resistant |
| Other | Acetophenone at 23°C | resistant |
| Other | Acetyl chloride at 23°C | not resistant |
| Other | Acetylene at 23°C | resistant |