To catalogue
Turbo Fuse Series 110 - Medical Devices
- Chemical Family
- Cyanoacrylates
Turbo Fuse Series 110 Medical devices advanced formula is designed to polymerize instantly by absorbing surface moisture. The product's performance has been tested with a variety of materials, and is recommended for a multitude of applications. The fast curing qualities make it especially desirable in high speed industrial production. Turbo Fuse Medical devices is ideal for use in applications that require good "wicking" characteristics and/or in close fitting applications approved for use on Medical Devices.
Product families
Applications
Building & Construction — Building Materials
- Pipes & Plumbing
Healthcare & Pharma — Medical
- Medical Devices & Assemblies
Product Families
Ready-to-Use Products — Adhesives & Sealants
- Anaerobic Adhesives
Other characteristics
- Brand
- Turbo Fuse
- Features
Fast Curing, General Purpose, Good Wicking, High Performance
- Product Type
- 1K (1 component) Adhesive
- Application Area
- Medical Devices
- Compatible Substrates & Surfaces
- Aluminum, Elastomers & Rubbers, Metal, Steel
- Color
- Transparent
- Markets
- Building & Construction
- Healthcare & Pharma
- Appearance
- Clear liquid, Clear hard (Cured)
- Shelf LIfe
- 1 Year
- Soluble In
- Acetone, MEK, Amide, Methylene Chloride
- Technology
- Ready-to-Use Products
- Certifications and Compliance
- ISO 10993
- Ready to Use Product Features
- Fast Curing
- General Purpose
- Good Wicking
- High Performance
- Compatible Substrates and Surfaces
- Aluminum
- Elastomers & Rubbers
- Metal
- Steel
Technical data
Table 1 of 3
4 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Base Compound (Resin) | Ethyl cyanoacrylate | — | — |
| Viscosity | 2 to 5 | cPs | — |
| Specific Gravity | 1.05 | — | — |
| Flash Point | 170 - 200 | °F | Tagliabue closed cup |
Table 2 of 3
5 rows| Characteristic | Value | Unit |
|---|---|---|
| Average Set Time (Full Cure 24 hours, Metal) | 5 - 10 | seconds |
| Average Set Time (Full Cure 24 Hours, Plastic) | 5 - 10 | seconds |
| Average Set Time (Full Cure 24 Hours, Rubber) | 2 - 5 | seconds |
| Average Strength (Steel) | 20.0 | N/mm² |
| Loctite® Equivalent | 4014.0 | — |
Table 3 of 3
6 rows| Characteristic | Value | Unit |
|---|---|---|
| Softening Temperature | 300 | °F |
| Service Temperature | -65 to 180 | °F |
| Hardness Barcol | 65 | — |
| Dielectric Constant (at 1 MHz) | 3.33 | — |
| Specific Resistance | 8.6x10² | Ω-cm |
| Gap Filling | 0.002 | inches |