Stanyl® TC154 is a high-performance polyamide that provides unmatched performance and value for demanding applications in which superior heat resistance, design stiffness, wear and friction, and process flow qualities are required. This high-performance polyamide 46 is used for applications in automotive, E&E, gears, and outdoor power equipment. Since it retains its mechanical properties at high temperatures up to 220 °C, this makes it ideal for extremely high-performance applications, where it outperforms PPA, PA6T, PA9T, and often PPS and LCP. A suitable processing technology for the product is injection molding. Special features include being heat-stabilized and thermally conductive.
Product families
Applications
- Consumer Goods — Appliances & Electronics
- Consumer Electronics
Product Families
- Polyamides
Other characteristics
- Brand
- Stanyl
- Polymer Name
- Polyamide 46 (PA 46)
- Additives Included
- Heat Stabilizer
- Processing Methods
- Injection Molding
- Markets
- Consumer Goods
- Electrical & Electronics
- Flame Rating
- UL 94 V0
- Technology
- Plastics
- Packaging Type
- Bags
- Boxes
- Silos
- Super Sacks
- Quality Standards
- UL Yellow Card (E47960)
- Material Features
- Flame Retardant
- Good Thermal Conductivity
- Heat Resistance
- Heat Stabilized
- Thermally Conductive
- UL Flame Rated
- Certifications and Compliance
- ISO 14001
- OHSAS
- REACH (Europe)
- UL 94
- Plastics and Elastomers End Uses
- Heat Sinks
- Plastics and Elastomers Functions
- Resin
- Heat Sinks in LED Lamps Application Data
Stanyl® TC PA46 reduces the weight of heat sinks with 50% compared to aluminum; Stanyl® TC PA46 allows for high level of design freedom compared to metal and yields 85% lower CO₂ footprint than with an equivalent die cast aluminum heat sinks; Stanyl® TC PA46 allows for reliable solutions due to its thermoconductivity (portfolio of several thermal conductive grades available)
- Plastics and Elastomers Processing Methods
- Injection Molding
Technical data
Table 1 of 7
5 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Tensile Modulus | 5100 / - | MPa | ISO 527-1/-2 |
| Stress at Break | 55 / - | MPa | ISO 527-1/-2 |
| Strain at Break | 2 / - | % | ISO 527-1/-2 |
| Charpy Notched Impact Strength (at +23°C) | 2 / - | kJ/m² | ISO 179/1eA |
| Izod Notched Impact Strength (at +23°C) | 2 / - | kJ/m² | ISO 180/1A |
Table 2 of 7
17 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Coefficient of Linear Thermal Expansion (parallel) | 0.48 / * | E-4/°C | ISO 11359-1/-2 |
| Coefficient of Linear Thermal Expansion (normal) | 0.48 / * | E-4/°C | ISO 11359-1/-2 |
| Thermal Conductivity in Plane | 1 / * | W/(m K) | ASTM E1461 |
| Thermal Conductivity Through Plane | 0.5 / * | W/(m K) | ASTM E1461 |
| Burning Behaviour (at 1.5 mm Nominal Thickness) | UL V-0 / * | class | IEC 60695-11-10 |
| Burning Behaviour (at 3.0 mm Nominal Thickness) | UL V-0 / * | class | IEC 60695-11-10 |
| Burning Behaviour 5V (at 1.6 mm thickness h) | 5VA / * | class | IEC 60695-11-20 |
| Glow Wire Flammability Index (at thickness 0.75 / - mm) | 960 / - | °C | IEC 60695-2-12 |
| Glow Wire Flammability Index (at thickness 3 / - mm) | 960 / - | °C | IEC 60695-2-12 |
| Glow Wire Ignition Temperature (at thickness 0.75 / - mm) | 750 / - | °C | IEC 60695-2-13 |
| Glow Wire Ignition Temperature (at thickness 3 / - mm) | 775 / - | °C | IEC 60695-2-13 |
| Relative Temperature Index (Electrical, 0.75 / * mm) | 140 / * | °C | UL746B |
Table 3 of 7
4 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Volume Resistivity | 1E13 / - | Ohm*m | IEC 62631-3-1 |
| Surface Resistivity | - / 1E13 | Ohm | IEC 62631-3-2 |
| Electric Strength | 30 / - | kV/mm | IEC 60243-1 |
| Comparative Tracking Index | 225 / - | V | IEC 60112 |
Table 4 of 7
1 row| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Viscosity Number | 140 / * | cm³/g | ISO 307, 1157, 1628 |
Table 5 of 7
3 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Water Absorption | 6.5 / * | % | Sim. to ISO 62 |
| Humidity Absorption | 1.9 / * | % | Sim. to ISO 62 |
| Density | 1520 / - | kg/m³ | ISO 1183 |
Table 6 of 7
2 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Molding Shrinkage (parallel) | 0.6 / * | % | Sim. to ISO 294-4 |
| Molding Shrinkage (normal) | 0.7 / * | % | Sim. to ISO 294-4 |
Химическая стойкость
377 rows| Characteristic | Value | Unit |
|---|---|---|
| Other | Acetaldehyde (40% by mass) at 23°C | resistant |
| Other | Acetamide (50% by mass) at 23°C | limited resistant, tests necessary to verify |
| Other | Acetamide (50% by mass) at >140°C | not resistant |
| Other | Acetic acid (10% by mass) at 100°C | not resistant |
| Other | Acetic acid (10% by mass) at 23°C | limited resistant, tests necessary to verify |
| Other | Acetic acid (95% by mass) at 23°C | not resistant |
| Ketones | Acetone at 23°C | resistant |
| Other | Acetophenone at 23°C | resistant |
| Other | Acetyl chloride at 23°C | not resistant |
| Other | Acetylene at 23°C | resistant |
| Other | Acrylic acid at 23°C | not resistant |
| Other | Aliphatic amines at 23°C | resistant |