Mascoat® Transportation-DTA
- Chemical Family
- Acrylics & Acrylates
Mascoat® Transportation-DTA is a composite ceramic insulation coating that provides an insulating barrier, protects personnel and blocks corrosion all in one application. The coating is specifically designed to be a multiple-purpose coating, solving painting and insulating issues.
Product families
- Protective Coatings
Other characteristics
- Brand
- Mascoat
- Features
Corrosion Resistant, Fast Cure, Low VOC, Moisture Resistant, Thermally Insulating; Excellent thermal insulation at low thickness; Excellent personnel protection; Prevents Corrosion Under Insulation (CUI); Provides condensation protection; Fast cure times; Low VOC Product; Easy application to irregular surfaces and tight spaces
- Product Type
- Insulating Coating, Waterborne Coating
- Insulating Coating
- Waterborne Coating
- Application Method
- Brush, Roller, Spray
- Base
- Water-based Acrylic Insulation Coating
- Usage
- Engine covers
- Undercarriages
- Roofs
- Firewalls
- Storage areas
- Generator
- Housings
- Doors
- Gloss
- Flat
- Safety
For minimum protection, Mascoat recommends an N95 particulate respirator mask. For additional protection, a half mask respirator with organic vapor cartridge can be utilized. Eye protection recommended due to spray application method.
- Markets
- Automotive & Transportation
- Paints & Coatings
- Priming
Self priming over non-ferrous materials (stainless steel & aluminum). Primer required for carbon steel substrates.
- Clean Up
- Equipment may be cleaned with soap & water.
- PACKAGING
Container Wet (with pail/lid) - 35 - 36 lbs/5 gallon pail; Net Contents - 32.2 lbs/5 gallon pail
- Shelf LIfe
- 18 months shelf life from manufacture date.
- Limitations
- Applications should not exceed 350˚F.
- Technology
- Ready-to-Use Products
- Labeling Claims
- Environmentally Friendly
- Application Methods
- Brush
- Roller
- Spray
Technical data
Table 1 of 3
6 rows| Characteristic | Value | Unit |
|---|---|---|
| Wet Weight | 6.4 - 6.5 | lbs/gal |
| Weight Dry Film To Area (20 mils DFT) | 0.046 | lbs/ft² |
| Volume Solids Content | 78 - 80 | % |
| Average Thickness per Coat (WFT, 70°F - 130°F) | 20 - 22 | mils |
| Practical Dry Coat Coverage (20 mils) | 50 - 55 | ft²/gal |
| VOC Content | 0.06 | g/l |
Table 2 of 3
4 rows| Characteristic | Value | Unit |
|---|---|---|
| Permeability | Low - None | perms |
| Pull Apart Strength | 200.0 | psi |
| Application Temperature | 60 - 300 | °F |
| Operation Temperature | max. 350 | °F |
Table 3 of 3
8 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Hardness (Average) | 68.0 | Shore A | ASTM D-2240 |
| Mandrell Bend | 2022-01-02 | " | ASTM D-522 |
| Pull Apart Strength | 200.0 | psi | ASTM D-4541 |
| Impact Testing (Direct) | 80.0 | in.lb | ASTM D-2794 |
| Impact Testing (Direct) | 40.0 | in.lb | ASTM D-2794 |
| Flammability | Pass | — | FM VSS 302 |
| Flame Developed | Class A | — | ASTM-E-84 |
| Smoke Developed | Class A | — | ASTM-E-84 |