Mascoat® 450EN
Mascoat® 450EN is to be used under insulating coatings or conventional insulation in highly corrosive environments. It is designed to provide CUI protection per NACE SP0198. When used under insulation, 450EN offers outstanding resistance to wet & dry cycling at high temperatures up to 450°F. The coating can be used on steel for offshore platforms, barges, refineries, petrochemical plants, power plants, pulp & paper mills, and many other areas as recommended. The coating can also be used to line steel tanks at a higher film thickness.
Product families
- Primers & Sealers
Other characteristics
- Brand
- Mascoat
- Features
Corrosion Resistant, Ease of Handling, High Temperature Resistance, Low VOC, Thermal Shock Resistant, Water Resistant; Excellent corrosion protection; Ambient temperature cure; Easy to apply; Excellent thermal shock resistance; Excellent build on edges; Single coat capability; High build formulation; VOC compliant
- Product Type
- Primer, Solventless & High Solids Coating
- Primer
- Solventless & High Solids Coating
- Application Method
- Brush, Roller, Spray
- Compatible Substrates & Surfaces
- Metal, Steel
- Finish
- Semi-gloss
- Safety
For minimum protection, Mascoat recommends an N95 particulate respirator mask. For additional protection, a half mask respirator with organic vapor cartridge can be utilized. Eye protection recommended due to spray application method.
- Markets
- Industrial
- Paints & Coatings
- Clean Up
- Cleanup with Reducer 3-400 or acetone.
- Shelf LIfe
2 years for both Parts A & B when stored inside at 40˚F - 110˚F.
- Limitations
- Continuous temperature - 425˚F
- Non-continuous temperature - 450˚F
- Discoloration may occur above 250˚F
- Technology
- Ready-to-Use Products
- Maximum Recoat
If the maximum recoat time is exceeded, the coating should be sweep blasted with fine aggregate to roughen surface.
- Application Methods
- Brush
- Roller
- Spray
- Application Conditions
Special reducing and application procedures are required outside these temperatures. Surface temperatures should be 5˚F above dew point to prevent condensation.
Technical data
Table 1 of 4
4 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Impact Resistance (Direct) | 80.0 | in.lbs | ASTM D-2794 |
| Adhesion | 3913.0 | psi | ASTM D-4541 |
| Abrasion Resistance (1 kg load/1000 cycles, Weight Loss CS 17 wheel) | 60.0 | mg | ASTM D-4060 |
| Molten Sulfur Cyclic Test | Pass | — | NACE SP0302 |
Table 2 of 4
1 row| Characteristic | Value | Unit |
|---|---|---|
| Flash Point | 0.0 | °F |
Table 3 of 4
9 rows| Characteristic | Value | Unit |
|---|---|---|
| Volume Solids Content (Mixed) | 79 - 81 | % |
| Wet Film Thickness | 200 - 300 | µ/Coat |
| Dry Film Thickness | 150 - 250 | µ/Coat |
| Theoretical Dry Coat Coverage (5 mils) | 1283.0 | ft²/gal |
| VOC Content (Unthinned) | 448.0 | g/l |
| VOC Content (Reducer 3-400) | 448.0 | g/l |
| VOC Content (Reducer 4-400) | 263.0 | g/l |
| Flash Point (Reducer 3-400) | 100.0 | °F |
| Flash Point (Reducer 3-400) | 0.0 | °F |
Table 4 of 4
1 row| Characteristic | Value | Unit |
|---|---|---|
| Flash Point | min. 200 | °F |