To catalogue
Nexa3D xPA11
- Chemical Family
- Polyamides
Nexa3D xPA11 is a bio compatible nylon material that is durable and flexible, making it optimal for use in exterior medical applications.
Product families
Applications
Healthcare & Pharma — Medical
- Medical Devices & Assemblies
Product Families
Plastics — 3D Printing Polymers
- Photoactive Resins
Other characteristics
- End Uses
- Medical Devices, Medical/Healthcare Applications
- Polymer Name
- Polyamide 11 (PA 11)
- Tensile Strength
- 45.0 - 45.0 MPa
- Processing Methods
- 3D Printing, Selective Laser Sintering
- Markets
- Healthcare & Pharma
- Technology
- Plastics
- Labeling Claims
- Biocompatible
- Material Features
- Biocompatible
- Durable
- Flexible
- Plastics and Elastomers End Uses
- Medical Devices
- Medical/Healthcare Applications
- Plastics and Elastomers Functions
- Resin
- Plastics and Elastomers Processing Methods
- 3D Printing
- Selective Laser Sintering
Technical data
Table 1 of 2
1 row| Characteristic | Value | Unit |
|---|---|---|
| Melt. point | 186 - 190 | °C |
Table 2 of 2
11 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Melting Point (Standard grades) | 186 - 190 | °C | ISO 11357 |
| Melting Point (Invent grades) | 201 | °C | ISO 11357 |
| Vicat Point | 181 | °C | ISO 306 |
| Tensile Modulus | 1500 | MPa | ISO 527 |
| Tensile Strength at Yield | 45 - 50 | MPa | ISO 527 |
| Elongation at Yield | 18 - 24 | % | ISO 527 |
| Tensile Strength at Break | 45 | MPa | ISO 527 |
| Elongation at Break | 45 | % | ISO 527 |
| Flexural Modulus (23°C) | 1200 | MPa | ISO 178 |
| Hardness (20°C) | 77 | Shore D | ISO 868 |
| Impact Strength (Charpy - Unnotched, 23°C) | No break | — | ISO 179 1eU |