FIL-A-GEHR® PEEK MG (MEDI)
- Chemical Family
- Polyether Ether Ketone (PEEK)
FIL-A-GEHR® PEEK MG (MEDI) is a high performance filament based on the material PEEK and is suitable for medical and pharmaceutical applications in direct body contact with tissue, bone, skin and mucous membrane up to 24 hours. They have been tested and evaluated by independent, accredited test laboratories and meet the following biocompatibility requirements: – ISO 10993-1/5/12/18 and USP Class VI.
Properties
- Physical Form
- Filament
Product families
Applications
- Other Automotive Applications
- Structural Components
- Equipment & Parts
- Other Industrial Applications
- Dental
- Surgical Instruments & Trays
- Healthcare Packaging
- Connectors
- Other Parts & Components
Product Families
- Thermoplastic Filament
Other characteristics
- Brand
- FIL-A-GEHR
- Density
- 1320.0 - 1320.0 kg/m³
- End Uses
Bearings, Connectors, Dental Applications, Pharmaceutical Packaging, Surgical Instruments
- Polymer Name
- Polyetheretherketone (PEEK)
- Color
- Natural
- Markets
- Automotive & Transportation
- Building & Construction
- Electrical & Electronics
- Healthcare & Pharma
- Industrial
- Printing & Packaging
- Properties
Excellent sterilisability with all standard methods (superheated steam, gamma, E-beam, EtO); Very high stability, rigidity and toughness; Very high thermal stability and heat deflection temperature; Very high creep resistance; Very high dimensional stability; Very high radiation resistance; Very high hydrolysis resistance; Good wear properties; Low water absorption; Inert
- Flame Rating
- UL 94 V0
- Technology
- Plastics
- Labeling Claims
- Odor-free
- Material Features
- Anti-Wear Properties
- Creep Resistant
- Dimensional Stability
- E-Beam Sterilizable
- Ethylene Oxide Sterilizable
- Excellent Hydrolysis Resistance
- Excellent Intercoat Adhesion
- Excellent Performance
- Certifications and Compliance
- FDA Compliant
- ISO 10993
- ISO 14001
- ISO 45001
- ISO 50001
- ISO 9001
- Regulation (EU) No. 10/2011 (PIM)
- UL 94
- Plastics and Elastomers End Uses
- Bearings
- Connectors
- Dental Applications
- Pharmaceutical Packaging
- Surgical Instruments
Technical data
Table 1 of 5
11 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Tensile Strength at Yield | 115 | MPa | ISO 527 |
| Elongation at Yield (S) | 7 | % | ISO 527 |
| Tensile Strength at Break | 67 | MPa | ISO 527 |
| Elongation at Break (R) | 16 | % | ISO 527 |
| Impact Strength (an) | No break | kJ/m2 | ISO 179 |
| Notch impact Strength (ak) | 4 | kJ/m2 | ISO 179 |
| Ball Indentation (Rockwell Hardness) | 250 (M 99) | MPa | ISO 2039 |
| Ball Indentation (Rockwell Hardness) | 250 (M 99) | — | ISO 2039 |
| Hardness | 90 | Shore D | ISO 868 |
| Flexural Strength (B 3,5 %) | 170 | MPa | ISO 178 |
| Modulus of Elasticity (Et) | 4210 | MPa | ISO 527 |
Table 2 of 5
5 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Specific Gravity | 1.32 | — | ISO 1183 |
| Water Absorption | 0.4 | % | ISO 62 |
| Humidity Absorption | 0.07 | % | ISO 62 |
| Maximum Permissible Service Temperature | 260 | °C | UL746B |
| Lower Permissible Service Temperature | -40 | °C | UL746B |
Table 3 of 5
7 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Vicat Softening Point (VST/B/50) | 250 | °C | ISO 306 |
| Heat Deflection Temperature (HDT/B) | 240 | °C | ISO 75 |
| Heat Deflection Temperature (HDT/A) | 158 | °C | ISO 75 |
| Coefficient of Linear Thermal Expansion | 0.47 | K-1.10-4 | ISO 11359 |
| Thermal Conductivity (20°C) | 0.25 | W/(m.K) | ISO 22007-4 |
| Glass Transition Temperature (Tg) | 143 | °C | ISO 3146 |
| Melting Temperature (Tm) | 340 | °C | ISO 3146 |
Table 4 of 5
6 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Volume Resistivity | min. 10^13 | Ω.cm | IEC 60093 |
| Surface Resistivity (Ro) | min. 10^13 | Ω | IEC 60093 |
| Dielectric Constant (1MHz) | 3.2 | — | IEC 60250 |
| Dielectric Loss Factor (1 MHz) | 3 | — | IEC 60250 |
| Dielectric Strength | 16 | kV/mm | IEC 60243-1 |
| Tracking Resistance | CTI 125 | V | IEC 60112 |
Table 5 of 5
6 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Bondability | Yes | — | — |
| Physiological Indifference (EEC) | Yes | — | — |
| Physiological Indifference (FDA) | Yes | — | — |
| Flammability | V-0 | — | UL 94 |
| Limiting Oxygen Index (LOI, 9) | 35 | % | ASTM D2863 |
| UV Stabilisation (6, 9) | Limited | — | — |