NuSil™ MED-4942
- CAS Number
- 68909-20-6
- Chemical Family
- Silicones
NuSil™ MED-4942 is a liquid silicone rubber.
Product families
Applications
- Pipes & Hoses
- Pipes & Plumbing
- Medical Devices & Assemblies
- Other Medical Applications
Product Families
- Silicone Elastomers
Other characteristics
- Brand
- NuSil
- End Uses
Drug Delivery Pens, Gaskets, Medical/Healthcare Applications, Valve Parts, Valves
- Polymer Name
- Silicone Elastomer
- Processing Methods
- Injection Molding
- Markets
- Agriculture & Feed
- Building & Construction
- Healthcare & Pharma
- Appearance
- White
- Cure
- Heat Cure
- Technology
- Elastomers
- HIGHLIGHTS
Two-part, white silicone system used with; injection molding equipmentCures with heat via addition-cure chemistry Designed to resist blocking on molded parts; caused by radiation sterilization1:1 Mix Ratio (Part A: Part B)
- Country Availability
- Brazil
- Canada
- China (Mainland)
- Mexico
- USA
- Use Instructions
Mixing; Combine Part A and Part B in a 1:1 mix ratio prior to use. Airless mixing, metering or dispensing equipment is recommended for production operations. If mixing by hand, take care to minimize air entrapment.; Vacuum Deaeration; Remove air entrapped during mixing by common vacuum deaeration procedure, observing all applicable safety precautions. Slowly apply full vacuum to a suitable container of at least four times the volume of material being de-aired. Hold vacuum until bulk deaeration is complete.; Substrate Considerations; Cures in contact with most materials common to biomedical assemblies, exceptions include: sulfur-cured organic rubbers, latex, chlorinated rubbers, some RTV silicones and unreacted residues of some curing agents.; Vulcanization; Curing of the blended elastomer is accelerated by heat. The pre-measured catalyst provides a fixed cure rate. Do not attempt to change molding times by mixing the two components in any other than a 1:1 ratio, as this will affect the properties of the elastomer. Only temperature adjustments should be employed to alter the rate of cure.
- Plastics and Elastomers End Uses
- Drug Delivery Pens
- Gaskets
- Medical/Healthcare Applications
- Valve Parts
- Valves
- Plastics and Elastomers Processing Methods
- Injection Molding
Technical data
Table 1 of 2
6 rows| Characteristic | Value | Unit |
|---|---|---|
| Durometer Type A | 40.0 | — |
| Tensile | 850 (5.86 ) | psi (MPa) |
| Elongat ion | 350.0 | % |
| Tear | 130 (22.93 ) | ppi (kN/m) |
| Mix Rat io | 0.042361111 | — |
| Specific Gravity | 1.17 | — |
Table 2 of 2
2 rows| Characteristic | Value | Unit |
|---|---|---|
| Cure at 150 °C | 10.0 | minutes |
| Cure System | Platinum | — |