To catalogue

Poly Top Seal CSx-2O

Poly Top Seal CSx-20 is a unique waterborne, non-flammable polysiloxane/teflon penetrating sealer. It is specifically engineered for the treatment of parking decks, bulk storage facilities, truck and rail shops, maintenance areas, veterinary clinics, animal kennels or area's that must have easy ice removal. Poly Top Seal CSx-20 will protect against moisture intrusion as well as oils, chlorines, grease and a variety of acids and solvents (not MEK). Poly Top Seal CSx-20 is a penetrating system that is not susceptible to U.V. degradation.

Product families

Ready-to-Use Products — Paints & Coatings
  • Primers & Sealers

Other characteristics

Brand
Poly Top Seal
Features

Cost Effective, Good Solvent Resistance, Grease Resistant, High Performance, High Temperature Strength, Long Term Protection, Low VOC, Low Water Absorption, Non-Toxic, Oil Resistant, UV Resistant

Product Type
  • Sealer, Waterborne Coating
  • Sealer
  • Waterborne Coating
Application Method
Spray
Compatible Substrates & Surfaces
Concrete
Markets
  • Building & Construction
  • Paints & Coatings
PACKAGE
Available in five (5) gallon pails.
Storage

Storage should be maintained in sealed containers between 40°F and 100°F and out of direct sunlight. Product is specially mixed to order with low shelf-life expectancy and should be used within 6-12 months post order.

Technology

The CSx-20 system utilizes unique a chemistry of polysiloxanes coupled with proprietary technologies to provide high performance products that are environmentally safe. Poly Top Seal CSx20 is a highly reactive, cross-linked polysiloxane, Teflon formulation that is capable of penetration rates 1/4" - 3/4" into the concrete. Broom finished surfaces may attain 1.5 inches. The formula attaches itself to the substrate particles by electrochemical means. During the curing process the system reacts with certain elements in the concrete to form a subsurface vapor permeable elastomeric membrane. The membrane allows the treated matter to breathe normally while impeding contaminants from spreading, wetting and ground moisture absorption through capillary channeling. Poly Top Seal CSx-20 may increase the slip coefficient when applied on smooth steel trowel finished surfaces.. Ready-to-Use Products

Labeling Claims
  • Low VOC
  • Non-Flammable
  • Non-Hazardous
  • Non-Toxic
Primary Benefits

Long-term performance.; Vapor permeable.; U.V. (Ultraviolet) resistant / extends product life.; Oil, Grease and Solvent resistant.; Very cost effective versus urethanes and epoxies.; Prevents the water absorption/retention required for the growth of fungi or algae.; Prevents adhesion of dirt and organic pollutants.; Very low VOC's / non-toxic / non-hazardous.; Provides protection in extreme temperatures (between -50°F and +225°F).

Application Methods

Spray. Poly Top Seal CSx-20 can be applied by means of spraying with a conventional, airless (60 psi or below), or Hudson pump up type sprayer. Make sure the masonry, brick and clay substrate to be treated is dry (15% moisture content maximum). Agitate the sealer as indicated on the label; utilize as iso not dilute or otherwise alter the material.

Surface Preparation

The material to be treated should be dry and free of non-integral dust, dirt, mildew, algae or alkali salts. If being applied to an existing structure, the substrate should be thoroughly washed to remove all efflorescence, dirt, mildew and fungi. Allow adequate time for drying prior to application. A light broom or shot blast surface is recommended. Surface can become slick without proper surface preparation, do not burnish surface.

Ready to Use Product Features
  • Cost Effective
  • Good Solvent Resistance
  • Grease Resistant
  • High Performance
  • High Temperature Strength
  • Long Term Protection
  • Low VOC
  • Low Water Absorption
Compatible Substrates and Surfaces
Concrete

Technical data

Table 1 of 1

10 rows
CharacteristicValueUnitMethod
Breathability96.6%ASTM D1653
Coverage (Poured in Place Concrete)150 - 300square feet per gallon—
Coverage (Pressed Concrete Pavers)100 - 200square feet per gallon—
Flash Pointmin. 212°F—
NCHRP 244 Chloride Absorption98.3%—
Penetration0.18 - 0.44in—
Simulated Wind Driven Rain (FS TTP 0035)Pass——
U.V. Resistance (QUV 7500 Hrs)Pass——
VOC Contentmax. 0.27lbs./gal—
Water Leakage99.4%ASTM E514

The Omnichem website uses cookies. By continuing to use the site, you consent to their use in accordance with our Privacy Policy and to the collection of analytics.