To catalogue

Armor Plate 999MP Multi-Purpose Epoxy Grout

Armor Plate 999MP Multi-Purpose Epoxy Grout is a three-component, high strength, 100% solids, epoxy grouting compound. It is primarily used to grout large machinery, support sole plates and rehabilitate concrete structures. Armor Plate 999MP exhibits early compressive strength, negligible shrinkage and is resistant to mechanical abuse and corrosive attack. Armor Plate 999MP is an ideal grouting material for use in these and other applications:; Equipment grouting for pumps and compressors Anchor bolt and rebar grouting Repairing spalled concrete Rebuilding concrete curbs Repairing concrete columns and concrete bases Deep pour applications to 12 inches.

Product families

Ready-to-Use Products — Construction Materials
  • Mortar & Grouts

Other characteristics

Brand
Armor Plate
Features

Acid Resistant, Chemical Resistant, Cost Effective, Fast Cure, Grease Resistant, High Flash Point, High Strength, Oil Resistant, Salt Resistance, Solvent Resistant, Steam Resistant, Water Resistant

Product Type
Grout
Mixing

Armor Plate 999MP is packaged as a three-part, premeasured system of Resin (A), Cure (B), and Aggregate (C). Resin and cure must be thoroughly mixed before aggregate is added. DO NOT add aggregate before resin and cure are properly mixed Mix the AP 999MP according to the following instructions: 1 Add Armor Plate 999MP Cure (part B) to Armor Plate 999MP Resin (part A). DO NOT add Aggregate at this time. 2 Mix Resin and Cure thoroughly for at least 2 minutes. Use an electric mixing blade, a horizontal agitator, or other mechanical equipment suited for producing homogenous mix. 3 Pour the completely mixed AP 999MP Resin and Cure into a concrete or mortar mixer. 4 Add one-half of the AP 999MP Aggregate (part C) and mix until it is thoroughly wetted. 5 Add the remainder of the Aggregate and mix until all of the aggregate is thoroughly wetted. 6 For smaller batches use a 3/4″ drill and mix one (1) gallon with 50 lbs of Aggregate (part C). 7 To increase flow, solvent approved by Wil-Cor, Inc. may be added.

Caution

Armor Plate 999MP is a low toxicity system, but allergic reaction may occur in some persons. Use Armor Plate 999MP in well ventilated areas and avoid breathing fumes or aggregate dust. Avoid skin contact if possible. Gloves and other protective equipment are recommended. Use soap and water to thoroughly clean contaminated areas of the body. In case of eye contact, thoroughly flush the eyes with water and seek immediate medical attention.

Markets
  • Building & Construction
  • Industrial
PACKAGING

Armor Plate 999MP is available in a pre-measured unit containing Component A (Resin), Component B (Cure/Hardener) and Component C (Aggregate), for a total weight per unit of 242 lbs. This unit yields 2.0 cu. ft. of mixed material.

Advantages

Easy to handle and place No mixing ratios to measure Packaged in pre-measured containers Grouts machinery in final aligned position Low exotherm for deeper pours High early strength High impact strength Superior resistance to fatigue Resistance to many chemicals Impervious to oil Moisture insensitive Strong bond to metal and concrete Unaffected by weathering and freeze/thaw cycling

Shelf LIfe

Armor Plate 999MP grout components must be kept dry. Both the epoxy liquid and aggregate must be stored in a dry shelter. Freezing will not harm any of the Armor Plate 999MP components. Parts A, B and C may be stored in sub-zero conditions, such as occur at Prudhoe Bay, Alaska. Both component A and B have a minimum 1 year in tightly sealed containers and Component C has an indefinite shelf life if kept dry.

Limitations

Do not use Armor Plate 999MP is base of the operating equipment to be grouted exceeds 150 °F on a continuous basis. If temperatures are greater, use Armor Plate 999 Heavy Equipment Grout.

Technology
Ready-to-Use Products

Technical data

Table 1 of 1

11 rows
CharacteristicValueUnitMethod
ColorGray——
ViscosityFlowable Grout——
Pot Life (65 °F)5.0hours—
Pot Life (77 °F)3.5hours—
Pot Life (90 °F)2.0hours—
Pour Depth (one lift)12.0inches—
Maximum Operating Temperature150.0°F—
Shrinkage0.0005in/inASTM C-531
Compressive Strength (Ambient Temperature)11800.0psiASTM C-579/Method B
Compressive Strength (Tensile Strength (ASTM C-307-61))2410.0psiASTM C-579/Method B
Compressive Strength (Flexural Strength (ASTM D-790))4680.0psiASTM C-579/Method B

The Omnichem website uses cookies. By continuing to use the site, you consent to their use in accordance with our Privacy Policy and to the collection of analytics.