To catalogue
Addiflam® SBI 20011 F NATUREL
- Chemical Family
- Polyamides
Product families
Applications
Applications
- Electrical & Electronics — Other Electrical & Electronics Applications
Automotive & Transportation — Automotive
- Exterior & Body
- Interior
Electrical & Electronics — Parts & Components
- Connectors
Product Families
Plastics — Engineering & Specialty Polymers
- Polyamides
Other characteristics
- Brand
- Addiflam
- Polymer Name
- Polyamide 6 (PA 6)
- Additives Included
- Flame Retardant
- Note
- dam
- specimens 48h after molding
- cond
- specimens conditioned according to ISO 291 et ISO 1110.
- Color
- Custom
- Markets
- Automotive & Transportation
- Electrical & Electronics
- Flame Rating
- UL 94 V0
- Technology
- Plastics
- Fire Resistance
Halogen and antimony free; Polyamid 6 halogen free flame retardant; Yellow Card UL94 : V0 «All Colors» - 0.8 ; 1.6 & 3mm; Certification : GWIT 775°C from 0.4mm to 3mm; Glow wire test GWFI : 960°C / 5 s.; LOI : 39%; CTI : 600 V; Ball Test > 125°C; Available in different colors
- Labeling Claims
- Environmentally Friendly
- Halogen-free
- Low Toxicity
- Material Features
- Flame Retardant
- High Efficiency
- High Performance
- Improved Glow Wire Performance
- Low Smoke Emission
- Low Toxicity
- Certifications and Compliance
- UL 94
- Plastics and Elastomers End Uses
- Electrical Connectors
Technical data
Table 1 of 5
17 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Charpy Notched Impact Strength (at -30°C) | 2.8 | kJ/m2 | ISO 179-1/1eA |
| Hardness (Cond) | 77 | Shore D | ISO 868 |
| Charpy Notched Impact Strength (cond) | 8 | kJ/m2 | ISO 179-1/1eA |
| Hardness (Dam) | 85 | Shore D | ISO 868 |
| Charpy Notched Impact Strength (dam) | 3 | kJ/m2 | ISO 179-1/1eA |
| Charpy Unnotched Impact Strength (cond) | NB | kJ/m2 | ISO 179-1/1eU |
| Charpy Unnotched Impact Strength (dam) | 87 | kJ/m2 | ISO 179-1/1eU |
| Elongation at Break (cond) | 200 | % | ISO 527-2/1A |
| Elongation at Break (dam) | 8 | % | ISO 527-2/1A |
| Flexural Modulus (cond) | 1000 | MPa | ISO 178 |
| Flexural Modulus (dam) | 3400 | MPa | ISO 178 |
| Izod Notched Impact Strength (cond) | 6.5 | kJ/m2 | ISO 180/1A |
Table 2 of 5
2 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Heat Deflection Temperature | 86 | °C | ISO 75-2/Af |
| Melting Point | 220 | °C | ISO 11357-3 |
Table 3 of 5
1 row| Characteristic | Value | Unit | Method |
|---|---|---|---|
| CTI | min. 600 | V | CEI 60112 |
Table 4 of 5
3 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Density | 1.16 | g/cm3 | ISO 1183-1 |
| Water Absorption (at 24H / 23°C) | 0.92 | % | ISO 62 |
| Water Absorption (at 30Min / 100°C) | 1.21 | % | ISO 62 |
Table 5 of 5
6 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| European Railway Reference (Classement R22) | HL 2 | — | NF EN 45545-2 |
| European Railway Reference (Classement R23) | HL 3 | — | NF EN 45545-2 |
| Falling Ball Test | min. 125 | — | CEI 60695-10-2 |
| Incandescent Glow Wire Flammability Test (at 2mm) | 960 / 5 | °C /s | CEI 60695-2-12 |
| Limit Oxygen Index | 38 | % | ISO 4589-2 |
| Vertical Burning (at 1.6mm) | V0 | — | Test 50W Ul94 |