To catalogue
Addiflam® SBI 20053 F
- Chemical Family
- Polyamides
Product families
Applications
Applications
- Electrical & Electronics — Other Electrical & Electronics Applications
Electrical & Electronics — Devices & Assemblies
- Automotive Electronics
Electrical & Electronics — Parts & Components
- Connectors
Electrical & Electronics — Wire & Cable
- Building Wires & Power Cables
- Other Wire & Cable Applications
Product Families
Plastics — Engineering & Specialty Polymers
- Polyamides
Other characteristics
- Brand
- Addiflam
- Polymer Name
- Polyamide 6 (PA 6)
- Additives Included
- Flame Retardant
- Note
- dam
- specimens 48h after molding
- cond
- specimens conditioned according to ISO 291 et ISO 1110.
- Markets
- Electrical & Electronics
- Flame Rating
- UL 94 V2
- Technology
- Plastics
- Labeling Claims
- Halogen-free
- Material Features
- Flame Retardant
- Certifications and Compliance
- UL 94
- Plastics and Elastomers End Uses
- Automotive Electronics
- Cables
- Electrical Connectors
- Wires
Technical data
Table 1 of 5
16 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Charpy Notched Impact Strength (cond) | 7 | kJ/m2 | ISO 179-1/1eA |
| Hardness (Cond) | 75 | Shore D | ISO 868 |
| Charpy Notched Impact Strength (dam) | 2.5 | kJ/m2 | ISO 179-1/1eA |
| Hardness (Dam) | 84 | Shore D | ISO 868 |
| Charpy Unnotched Impact Strength (cond) | NB | kJ/m2 | ISO 179-1/1eU |
| Charpy Unnotched Impact Strength (dam) | 60 | kJ/m2 | ISO 179-1/1eU |
| Elongation at Break (cond) | 200 | % | ISO 527-2/1A |
| Elongation at Break (dam) | 6 | % | ISO 527-2/1A |
| Flexural Modulus (cond) | 1000 | MPa | ISO 178 |
| Flexural Modulus (dam) | 3400 | MPa | ISO 178 |
| Izod Notched Impact Strength (cond) | 6 | kJ/m2 | ISO 180/1A |
| Izod Notched Impact Strength (dam) | 2.5 | kJ/m2 | ISO 180/1A |
Table 2 of 5
2 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Heat Deflection Temperature | 86 | °C | ISO 75-2/Af |
| Melting Point | 220 | °C | ISO 11357-3 |
Table 3 of 5
1 row| Characteristic | Value | Unit | Method |
|---|---|---|---|
| CTI | min. 600 | V | CEI 60112 |
Table 4 of 5
3 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Density | 1.17 | g/cm3 | ISO 1183-1 |
| Water Absorption (at 24H / 23°C) | 0.92 | % | ISO 62 |
| Water Absorption (at 30Min / 100°C) | 1.21 | % | ISO 62 |
Table 5 of 5
6 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| European Railway Reference (Classement R22) | HL 2 | — | NF EN 45545-2 |
| European Railway Reference (Classement R23) | HL 3 | — | NF EN 45545-2 |
| Falling Ball Test | min. 125 | °C | CEI 60695-10-2 |
| Incandescent Glow Wire Flammability Test (at 2mm) | 960 / 5 | °C /s | CEI 60695-2-12 |
| Limit Oxygen Index | 33 | % | ISO 4589-2 |
| Vertical Burning (0.8-1.6 at 3mm) | V2 | — | Test 50W Ul94 |