FluoSolv® AP
FluoSolv® AP is a proprietary blend of nonflammable hydrofluoroethers (HFEs) and trans-1,2- dichloroethylene (t-DCE) and alcohol engineered for defluxing as well as white residue removal. It is a drop-in replacement for defluxing blends of n-propyl bromide (nPB) and similar vapor degreasing solvents. It can also be used as a substitute for other cleaners such as Asahi AK-225 (blend of HCFC-225 ca/cb) & HCFC-141b both of which are ozone depleting substances and have been banned from production.
Properties
- Physical Form
- Liquid
Product families
Applications
- Industrial Cleaning
- Institutional & Catering
Product Families
- Industrial Cleaners
Other characteristics
- Brand
- NuGenTec FluoSolv
- Features
- Degreasing, Grime Cleaning, Low Toxicity
- Product Type
- Cleaner, Degreasers, Rust Removers
- Cleaner
- Degreasers
- Rust Removers
- Application Area
- Machine Parts
- Certifications & Compliance
- ISO 14001, ISO 9001
- Compatible Substrates & Surfaces
Aluminum, Brass, Ceramic, Copper, Elastomers & Rubbers, Metal, Plastics
- Markets
- HI&I Care
- Storage
FluoSolv™ AP is thermally & chemically a very stable solvent. It is non-reactive,has low water solubility and will not oxidize or degrade when exposed to air. It is not affected by any sunlight or other sources of UV radiation. Common industrial practice should be implemented for storage; keep away from human food source and extreme temperature conditions. Freezing temperatures will cause the drums to compress and hot conditions will balloon the drum. The product in any case is perfectly usable.
- Appearance
- Clear, colorless
- Technology
- Ready-to-Use Products
- Worker Safety
Data from acute toxicity studies of various ingredients has demonstrated that FluoSolv™AP blend has low toxicity. It has a calculated AEL (Acceptable Exposure Limit) of 335 ppm based on its individual components. None of the ingredients in FluoSolv™ AP have any chronic or acute toxicity associated with them which makes it a worker friendly solvent. Please refer to the MSDS for information on detailed exposure limits and toxicity-related data. NuGenTec FluoSolv™ AP exhibits no closed cup or open cup flash point and is not classified as a flammable liquid per established definitions by NFPA or DOT, however being volatile, vapors may become flammable in air. Flash point data and vapor flammability limits in air are shown.
- Packaging Type
- Bottles
- Drums
- Pails
- Labeling Claims
- Low Toxicity
- Non-Carcinogenic
- Non-Flammable
- Solvent Recycling
FluoSolv™ AP is a stable azeotropic blend easy to reclaim and reuse by simple distillation process. Commercially available modular recycling units can easily be added to realize sizable savings in solvent usage. Solvent recovery yields are typically in the range of 80 to 95%.
- Chemical Inventories
- TSCA (USA)
Technical data
Table 1 of 3
12 rows| Characteristic | Value | Unit |
|---|---|---|
| Boiling Point | 43.0 | °C |
| Density (At 25°C) | 1.26 | kg/liter |
| Surface Tension (At 25°C) | 21.0 | dyne/cm |
| Viscosity (At 25°C) | 0.46 | cPs |
| Vapor Pressure (At 25°C) | 41.0 | kPa |
| Heat of Vaporization (At bp) | 64.3 | cal/g |
| Global Warming Potential | max. 30 | — |
| Ozone Depleting Chemical | No | — |
| Volatile Organic Compounds (VOC) | 756.0 | g/l |
| Allowable Exposure Limit (AEL) | 352.0 | ppm |
| Worker Exposure Ceiling | No | ppm |
| KB Value | 92.0 | — |
Table 2 of 3
4 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Flash Point (CC) | None | — | ASTM D93 |
| Flash Point (OC) | None | — | ASTM D1310 |
| Flammability in Air (Lower Explosivity) | 6.1 | vol% | ASTM E681 |
| Flammability in Air (Upper Explosivity) | 11.1 | vol% | ASTM E681 |
Table 3 of 3
6 rows| Characteristic | Value | Unit |
|---|---|---|
| Hydrofluoroethers | max. 30 | wt% |
| Trans-dichloroethylene | min. 70 | wt% |
| Iso-propyl Alcohol | max. 5 | wt% |
| Water | max. 100 | ppm |
| Non-Volatile Residue (Drums) | max. 100 | ppm |
| Non-Volatile Residue (Pails) | max. 200 | ppm |