NANOMYTE® TC-5001-UVP
NANOMYTE® TC-5001-UVP is a single component formulation designed to protect zinc-plated and galvanized steel from corrosion and degradation. The product is a hard, dense nanocomposite coating that provides barrier protection for the alloy surface. The coating resists scratching and chipping, and strongly adheres to the substrate. The formulation has enhanced weatherability and is designed to meet customers’ requirements for film thickness and curing conditions.
Properties
- Physical Form
- Liquid
Product families
- Top Coats
Other characteristics
- Brand
- NANOMYTE
- Features
Excellent Substrate Adhesion, Good Scratch Resistance, Good UV Protection
- Product Type
1K (1 component) Coating, Solventborne Coating, Top Coat; 1K (1 component) Coating; Solventborne Coating; Top Coat
- Application Method
- Brush, Roll Coater, Spray
- Compatible Substrates & Surfaces
- Composites, Metal, Plastics, Steel
- Curing
- Room Temperature Curing (25 °C)
- Under ambient conditions, a single coat will be dry to the touch in 1-2 hours and cured in 24 hours.
- Accelerated Curing (105 °C – 150 °C)
- Alternatively, the coating can be applied to the surface, dried in ambient air for 10 minutes, and then heated to at least 105 °C for 1 hour. An oven, blow dryer or heat gun may be used (maximum temperature is 150 °C). After heating, coated parts should be allowed to cool before handling. TC-5001-UVP will completely wet bare metal surfaces if properly prepared or if primed / painted. Only one coat is required to cover substrates, but multiple coats are allowable. Under ambient conditions, a single coat is 5 - 15 μm (0.2 – 0.6 mil) thick and will be dry to the touch in 1-2 hours and cured in 24 hours. Multiple coats can be applied in 10 minute intervals while the previous coat is still tacky. Two to three coats should result in a final coating that is 25 - 40 μm (1-1.5 mil) thick.
- Surfaces
- Zinc-plated and Galvanized Steel
- Technology
- Ready-to-Use Products
- Labeling Claims
- Chrome-free
- Application Notes
- Test Area
- Given the wide variety of metals and the various methods and environments of application, it is advisable to first use TC-5001 on a test piece or in an inconspicuous area to evaluate the resulting adhesion and appearance. There will often be some enhancement in luster (gloss) from the original surface. TC-5001-UVP is a clear coating, however on some white paints or powder coats, the color may be altered to appear off-white or slightly yellow, particularly if a thick coat is applied.
- Clean Up
- Clean tools and flush equipment thoroughly with acetone immediately after application is completed and before product dries. Once the coating is dry, solvent cleaning is no longer effective.
- Care & Maintenance
- For normal cleaning, wash the coated surface with a hose or wipe down with a damp cloth to remove dirt and spills on the surface. Although TC-5001-UVP is scratch resistant, it is not scratch proof. Do not use abrasive cleaners or scouring pads. If an area becomes damaged or is mechanically abraded, lightly sand the area with 220 grit sandpaper and reapply the coating. If the substrate itself is damaged, make the necessary repairs first, then re-apply TC-5001-UVP.
- Weatherability and UV Protection
- For best performance, when applying to UV-sensitive surfaces (e.g., plastics, composites), apply as thick a coating as possible, and/or ensure a minimum DFT of 0.5 mils (10-15 microns). Select the appropriate surface preparation protocol (cleaning and/or surface treatment, priming) and test to ensure coating adhesion has been maximized. Some surfaces (e.g., certain paints, plastics and composites) may require a primer, such as NANOMYTE® SR-Primer. Samples intended for weatherability testing should be conditioned for a minimum of 1 week at 25°C with at least 50% relative humidity.
- Application Methods
- Brush
- Roll Coater
- Spray
Technical data
Table 1 of 2
1 row| Characteristic | Value | Unit |
|---|---|---|
| Solids Content | 18 - 20 | % |
Table 2 of 2
6 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Coverage | 800 - 1200 | ft²/gallon | — |
| Curing Temperature | 20 - 150 | °C | — |
| Recommended Thickness per Coat (Dry mils) | 0.5 - 1.2 | — | — |
| Recommended Thickness per Coat (Wet mils) | 1.5 - 2.0 | — | — |
| VOCs | max. 100 | g/L | — |
| Weatherability (DFT = 0.5 mils/10 - 15 μm) | min. 1,000 | hours | ASTM D4587 (G154, Cycle 1) |
