To catalogue

CIM® 800

Chemical Family
Urethanes

CIM® 800 is a tough, weather durable, waterproofing coating specifically formulated to meet the demands of waterproofing above or below grade. This two component, cold, liquid applied urethane coating adheres to most materials to form a permanent seamless barrier to water. It is especially well suited for roofs over critical spaces (e.g. clean rooms, control rooms), green roofs, plaza decks, areas with multiple penetrations and curbs, and between-slab waterproofing.

Other characteristics

Brand
CIM
Features

Excellent Coating Performance, Fast Curing, Good Toughness, Good Weather Stability, Water Resistant

Product Type
2K (2 component) Coating
Application Method
Roller, Trowel
Compatible Substrates & Surfaces
Concrete, Glass, Metal, Steel, Wood
Mixing

DO NOT THIN. DO NOT HAND MIX. Begin mixing each pail (4.5 gal.) of CIM 800 Premix using a power mixer (e.g. 1/ 2" drill and an eight inch mud mixer). Do not draw air into the mix. While mixing, slowly add one jug (0.5 gal.) of CIM 800 Activator to the pail and mix thoroughly for 3 FULL MINUTES. The proportions are pre-measured. DO NOT ESTIMATE. Mixing Jigs and Timers are available from C.I.M. Industries to help eliminate mixing errors and increase productivity on the job. See C.I.M. Industries' Instruction Guide, "Mixing CIM Premix and Activator" (IG–8).

Markets
Building & Construction
Pot Life

About 45 minutes. Working time depends on temperature and method of application. Working time for spray application requirements will be significantly shorter.

PACKAGING

CIM 800 is available in mixed units of 5 gallons. Each unit consists of a container of premix and a smaller container of activator. Quantities have been premeasured to provide the proper mixing ratio, leaving sufficient room in the premix container to facilitate adequate mixing. Do not estimate proportions.

Shelf LIfe
1 year (Activator), 2 years (Premix)
Precaution

Avoid contamination with water or moisture. Keep all pails and jugs tightly closed until ready for use. All equipment, air supplies, and application substrates must be ABSOLUTELY DRY. Do not apply in wet weather or when rain is imminent or when the CIM 800 or the substrate may become wet within 4 hours after coating. Use caution when applying CIM 800 in confined spaces.

Technical data

Table 1 of 1

31 rows
CharacteristicValueUnitMethod
Solids by Volume (1448 dry mils x sq. ft./gal.)90.0%—
VOC95 (0.80)g/l (lb./gal.)—
Abrasion Resistance (Loss)1.2mgASTM D4060 Taber Abraser CS-17 Wheel, 1000 gr./1000 rev.
Adhesion to Concrete (Dry)350.0psiElcometer
Deflection Temperature (Minimum Use Temperature)max. -40ºFASTM D648
Density Premix8.0Ibs./gal.—
Density Activator10.1Ibs./gal.—
Density Mixed & Cured8.5Ibs./gal.—
Elastomeric WaterproofingExceeds all criteria—ASTM C836
Elastomeric WaterproofingExceeds all criteria—ASTM C957
Extension to Break400.0%ASTM D412
FlammabilityPass/combustible substrate—ASTM D2859