SOLIMIDE® AC-530
SOLIMIDE® AC-530 polyimide foam is utilized in aircraft, aerospace and industrial markets as a lightweight, non-wicking, thermal and acoustic insulation material where low fire, toxicity and smoke generation are critical. It is formaldehydefree and demonstrates excellent long term stability under humid conditions and after temperature cycling. SOLIMIDE® AC-530 insulation is used in a variety of applications, including aircraft fuselage, under floor, ECS ducts and equipment, as well as expansion and contraction joints in cryogenic environments. The foam can be cut into numerous shapes and sizes, and is compatible with many different facings, coatings and adhesives to meet end-use requirements.
Product families
- Fuel Systems
- Equipment & Parts
- Fillers Levellers & Joints
- Aerospace & Aviation
Other characteristics
- Brand
- SOLIMIDE
- Density
- 5.8932032 - 5.8932032 kg/m³, 5.9 - 5.9 kg/m³
- End Uses
- Aerospace Applications, Aircraft Fuselage
- Aerospace Applications
- Aircraft Fuselage
- Foam Type
- Open Cell Foam
- Markets
- Automotive & Transportation
- Building & Construction
- Industrial
- Product Type
- Foam
- Technology
- Ready-to-Use Products
- Product Families
- Ready-to-Use Products — Foams
- Ready to Use Product Features
- Excellent Flexibility
- Flame Retardant
- Good Stability
- High Resilience
- High Temperature Resistance
- Hydrolysis Resistant
- Light Weight
- Specifications and Certifications
Boeing BMS 8-300; Airbus AIMS 04-14-004; Boeing (Douglas) DMS 2330; ASTM C 1482; KBR TS (Pipe Supports, Components and Fabricated Assemblies
Technical data
Table 1 of 1
8 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Density | max. 0.37 (5.9) | lb/ft³ (kg/m³) | ASTM D3574 Test A, ISO 845 |
| FAA Radiant Panel FAR 25.856(a) | Pass | — | — |
| Smoke Developed Index Flaming & Non-flaming Modes | max. 5 | — | ASTM E662 |
| Noise Reduction Coefficient (NRC), 1 in (25mm) | 0.7 | — | ASTM C423 and E795, Mounting A |
| Max Continuous Use Temperature | 400 (200) | °F (°C) | — |
| Thermal Conductivity (75°F (24°C)) | 0.36 (0.052) | BTU-in/hr-ft²-°F (W/mK) | ASTM C518 |
| Offgassing / Outgassing TMI | max. 1.0 | % | ASTM E595 |
| Offgassing / Outgassing CVCM | max. 0.1 | % | ASTM E595 |