STEPCOTE® W-849
STEPCOTE® W-849 stands as a formidable wetting agent designed for waterborne coatings. Its incorporation can happen during the letdown phase of production or after final formulation. Despite its primary role being a wetting agent, its influence extends positively to crucial coating properties such as gloss, color acceptance, wet scrub resistance, hiding, corrosion resistance, and washability.
Properties
- Physical Form
- Liquid
Identification
- CASE Ingredients Functions
- Wetting Agent
Product families
- Dispersing & Wetting Additives
Other characteristics
- Brand
- STEPCOTE
- End Uses
Solventless & High Solids Coating, Waterborne Coating
- Functions
- Wetting Agent
- Labeling Claims
- APEO-Free, VOC-free
- APEO-Free
- VOC-free
- Markets
- Paints & Coatings
- Appearance
- Hazy liquid (at 25°C)
- Clearances
The international inventories (country clearances) of STEPCOTE W-849 can be found in Section 15 of the Safety Data Sheet (SDS). It is the responsibility of the formulator to review the chemical control regulations for each country where the end product is intended to be sold or used.
- Applications
Paints & Coatings — Other Paints & Coatings Applications
- Coating Type
- Solventless & High Solids Coating
- Waterborne Coating
- Technology
- CASE Ingredients
- Packaging Type
- Bulk
- Standard Packaging
- STEPCOTE W-849 is available in bulk quantities.
- Handling
- Bulk Storage Information
- Elevated storage temperature may be desirable to maintain ease of pumping, but product should be stored long term at ambient temperature.
- Non-Bulk Storage Information
- STEPCOTE W-849 which has been stored in drums at temperatures below 10 °C (50 °F) may thicken or solidify. It may be fluidized by warming with a drum heater or in a steam room. Drums should be vented prior to heating to avoid excessive pressure build up. Product temperatures over 54 °C (130 °F) are not recommended.
- Safety precautions (gloves and safety goggles-face shield, if splashing may occur) should be employed when handling STEPCOTE W-849. Avoid contact with the eyes, nose and skin. Wash thoroughly after handling material.
- Chemical Inventories
- AICS (Australia)
- DSL (Canada)
- ENCS (Japan)
- IECSC (China)
- NZIoC (New Zealand)
- PICCS (Phillipines)
- TSCA (USA)
Technical data
Table 1 of 1
6 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Actives Content | 100 | % | — |
| Density (at 25°C) | 1.03 | g/ml | — |
| Flash Point | min. 94 | °C | PMCC Flash Point Tester |
| pH (in 1% aqueous) | 2.5 | — | — |
| Pour Point | max. -18 | °C | — |
| Regulated Volatile Organic Chemicals | 0 | % | U.S. EPA |