To catalogue
Murflor® + Carbon
- Chemical Family
- Fluoropolymers
Murflor® + Carbon is used, for example, when electrical conductivity is required and Original Material "S"® Black Antistatic cannot be used because the ambient temperature is too high. Production based on PTFE-C. The integration of 25% carbon increases the wear resistance, hardness, and creep strength of this material.
Product families
Applications
Applications
- Industrial — Other Industrial Applications
Industrial — Chemical & Industrial Manufacturing
- Other Industrial Applications
Product Families
Plastics — Engineering & Specialty Polymers
- High Performance Thermoplastics
Other characteristics
- Brand
- Murflor
- Polymer Name
- Polytetrafluoroethylene (PTFE)
- Fillers Included
- Carbon Black
- Markets
- Industrial
- Capability
- Murflor®+ Carbon Black
- Sliding guides and slide bearings
- Technology
- Plastics
- Material Features
- Good Sliding Properties
- Low Slip
- Wear Resistant
- Plastics and Elastomers Functions
- Resin
Technical data
Table 1 of 4
6 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Breaking Elongation | 100 | % | ISO 5271/2 |
| Coefficient of Sliding Friction (Dry)⁶ | 0.12 | μ | — |
| Notch Impact Toughness (Charpy) | 83 | kJ/m² | ISO 1791/1eA |
| Pressure Test (Compression Strength at 1% Nominal Compression) | 10 | MPa | ISO 604 |
| Sliding Abrasion⁶ | 1 | μm/km | — |
| Yield Stress | 15 | MPa | ISO 5271/2 |
Table 2 of 4
3 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Code | PTFE - C | — | ISO 10431 |
| Density | 2.1 | g/cm³ | ISO 11831 |
| Material Colour | Black | — | — |
Table 3 of 4
8 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Burning behaviour as per UL94 (Sample thickness 3/6 mm) | V0/V0 | — | — |
| Glass Transition Temperature | 127 | °C | ISO 113571/2 |
| Heat Conductivity (23°C) | 0.58 | W/(K x m) | — |
| Linear Thermal Coefficient of Expansion (Average Value between 23 and 100°C) | 95 x 10⁻⁶ | m/(K x m) | — |
| Lower Service Temperature⁴ | -200 | °C | — |
| Melting Temperature | 330 | °C | ISO 113571/3 |
| Upper Service Temperature Constant in Air (20000h)³ | 260 | °C | — |
| Upper Service Temperature in Air (Short-term)² | 300 | °C | — |
Table 4 of 4
2 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Specific Surface Resistance | min. 10⁶ | Ω | IEC 60093 |
| Specific Contact Resistance | min. 10⁻⁶ | Ω x cm | IEC 60093 |