Shanghai Sunwise Chemical OTS65 Tooling Prepreg has been formulated to give a robust surface finish with out of autoclave processing. It can be supplied on carbon or glass formats.
Product families
Applications
- Renewable Energy
- Marine
Product Families
- Thermoset Prepregs
Other characteristics
- Functions
- Prepreg
- Polymer Name
- Epoxy Resins & Compounds
- Processing Methods
- Out of Autoclave Prepreg
- Markets
- Automotive & Transportation
- Industrial
- Key Features
Cure temperature from 65°C to 90°C; Service temperature up to 125°C after post cure; Low CTE and shrinkage; Work life at 20°C: up to 21 days; Storage life at -18°C: 12 months; Very low VOC content – no added solvents during manufacture; Out of autoclave
- Technology
- Composite Materials
- Packaging Type
- Bags
- Labeling Claims
- Low VOC
- Health and Safety
This material contains epoxy resin which can cause allergic reactions with skin contact and must avoid repeated and prolonged skin contact.; The following precautions must be taken when using epoxy resin prepregs:; Overalls must be worn; Impervious gloves must be worn.; Curing schedule is meant to be as a guide only and is subject to local conditions.; To avoid exotherm, particular care must be taken with thick laminates.; Ramp rates must not exceed 1.0°C/min during initial cure and 0.3°C/min during post cure.
- Material Features
- Good Surface Appearance
- Low Shrinkage
- Storage and Out Life
This material should be kept frozen at -18°C. It must be kept sealed in a polythene bag which must not be opened until fully thawed to room temperature. If the material is not fully used, then the material must be resealed in the polythene bag to prevent moisture absorption.
- Typical Applications
- Out of autoclave tooling
- Recommended Cure Cycle
For optimum results out of autoclave, it is recommended that the initial cure is held at 65°C for a minimum of 2 hours.; Curing Schedule is meant to be a guide only and is subject to local conditions.; To avoid exotherm particular care must be taken with thick laminates.; Ramp rates must not exceed 1.0°C per minute during initial cure.; Ramp rates must not exceed 0.3°C per minute during post cure (free standing).
- Composite Materials Functions
- Prepreg
- Composites Processing Methods
- Out of Autoclave Prepreg
Technical data
Table 1 of 1
4 rows| Characteristic | Value | Unit |
|---|---|---|
| Cure Temperature | 65 - 90 | °C |
| Tg Onset | 129 | — |
| Tg Peak | 143 | — |
| Service Temperature | 125 | °C |