To catalogue

Duro-Bond PFA

Chemical Family
Fluoropolymers

Duro-Bond PFA is a chemical resistant membrane produced from the copolymerization of tetrafluoroethylene and perfluoroalkoxy resin.

Properties

Physical Form
Sheets

Other characteristics

Brand
EC Duro-Bond
Color
Transparent
End Uses

Automotive Applications, Automotive Exterior Parts, Automotive Interior Parts, Chemical Process, Industrial Applications, Semiconductor Applications

Features

Chemical Resistant, Corrosion Resistant, Good Reactivity

Polymer Name
Perfluoroalkoxy Polymer (PFA)
Tensile Strength
24.0 - 30.0 MPa
Usage

Duro-Bond PFA lined equipment is used in many ultra-high purity applications in the semiconductor, pharmaceutical, and chemical industries. The outstanding corrosion protection provided by Duro-Bond PFA broadens equipment service capabilities and extends its useful life. Its superior chemical resistance, together with its excellent adhesive bonding characteristics, makes Duro-Bond PFA a high performance lining material for almost any corrosive or high purity application.

Hazard

Thermal decomposition - PFA starts to decompose at 260°C; Hazardous decomposition products - Gaseous fluorinated hydrocarbons (fluoro-olefins, carbonyl fluoride and hydrogen fluoride). Scrap PFA must not be incinerated.; Hazardous reactions - Traces of COF2 are evident at around 350°C.; Transportation classifications - PFA is not classified as a hazardous material. No special precautions or procedures need be followed to transport PFA resin or sheet lining.

Markets
  • Automotive & Transportation
  • Electrical & Electronics
  • Industrial
Technology
Elastomers
Safety Issues

PFA resins are nonvolatile and safe at normal room temperatures. Good safety practice requires the use of adequate ventilation and respirators when processing PFA. Heating PFA may produce fumes and gasses that are irritating or toxic. Care must be taken to avoid contamination of smoking tobacco or cigarettes.

Labeling Claims
  • High Purity
  • Odor-free
Product Families
Elastomers — Parts & Shapes
Testing Methods

All lined surfaces are visually inspected for surface defects. Any special dimensional tolerances required after lining are also checked.. All lined areas are then spark tested for pinhole leaks using a dielectric spark tester adjusted to 10,000 volts. The tester is moved constantly and quickly over the lining surface to prevent a burn through.

Material Features
  • Chemical Resistant
  • Corrosion Resistant
  • Good Reactivity

Technical data

Table 1 of 1

12 rows
CharacteristicValueUnit
Chemical CharacterizationThermoplastic fluoroCarbon polymer—
Melting point300-310°C
Upper Service Temperature260.0°C
Density (23°C)2.15g/cm3
Tensile Strength24-30N/mm2
Elongation at Break300.0%
Solubility in waterInsoluble—
Hardness DurometerD 55—
Water Absorptionmax. 0.03—
Oxygen Indexmin. 95%
FlammabilityV-0—
Thermal Expansion Coefficient 23 -150°C16 x 10-5mm/mm/°C

The Omnichem website uses cookies. By continuing to use the site, you consent to their use in accordance with our Privacy Policy and to the collection of analytics.