Fluon+™ FP-E-93000 XL NATURAL LF

AGC Chemicals Americas, Inc. Fluon+™ FP-E-93000 XL NATURAL LF contains a crosslinking promoter in an ETFE (ethylene tetrafluoroethylene) polymer matrix. This cross-linkable compound is based on Fluon® ETFE and is supplied in cylindrical pellet form, approximately 3.2 mm in length by 2.0 mm in diameter.

Properties

Physical Form
  • Masterbatch
  • Pellets
  • Solid

Product families

Applications

Electrical & Electronics — Wire & Cable
  • Jacketing & Insulation

Product Families

Plastics — Masterbatches
  • Additive Masterbatches
Plastics — Polymer Additives
  • Catalysts Initiators & Crosslinkers

Other characteristics

Brand
Fluon+
Carrier
  • Ethylene Tetrafluoroethylene (ETFE), Resin-based
  • Ethylene Tetrafluoroethylene (ETFE)
  • Resin-based
Features

Abrasion Resistant, Good Flammability Properties, Increased Tensile Strength

Functions
Crosslinking Agent
Processing Methods

Compression Molding, Extrusion, Injection Molding

Markets
Electrical & Electronics
Benefits

Cross-linking ETFE increases mechanical properties such as scrape abrasion, cut-through resistance, and tensile strength, especially at elevated temperatures. Flammability of the cross-linked polymer is also improved.

Processing

This ready-to-use product can be processed using conventional thermoplastic techniques such as compression and injection molding and melt extrusion under standard ETFE operating conditions.. The processed article can be cross-linked using electron-beam radiation or gamma radiation. It is strongly recommended that process equipment exposed to molten resin be made of corrosion-resistant metals such as Monel, Inconel, or Hastelloy.

Technology
Plastics
Packaging Type
  • Drums
  • Pails
Material Features
  • Abrasion Resistant
  • Good Flammability Properties
  • Increased Tensile Strength
Handling Precautions

Heating Fluon® and Fluon+™ products in excess of 750°F (399°C) can produce toxic fumes. It is, therefore, necessary to provide local exhaust ventilation in areas where Fluon® products are exposed to high temperatures. Avoid breathing fumes or contaminating smoking tobacco with fumes, powder, or dust.. Thermal decomposition of this product will generate hydrogen fluoride, which is corrosive. Corrosion resistance materials are required for prolonged contact with molten resin.

Safe Use and Handling

A summary of the hazards, as defined by OSHA Hazard Communication Standard, 29 CFR 1910.1200 for this product are: Physical hazards: None Health hazards: None. FOR ADDITIONAL INFORMATION AND HANDLING INSTRUCTIONS READ AGC CHEMICALS AMERICAS, INC. MATERIAL SAFETY DATA SHEET.

Plastics and Elastomers End Uses
  • Cables
  • Wires
Plastics and Elastomers Functions
Crosslinking Agent
Plastics and Elastomers Processing Methods
  • Compression Molding
  • Extrusion
  • Injection Molding

Technical data

Table 1 of 1

8 rows
CharacteristicValueUnitMethod
Bulk Density880grams/literASTM D-1895
Dielectric Constant (at 1mHz, 23°C)2.6—ASTM D-150
Dielectric Loss Tangent (at 23°C,1mHz)0.0007—ASTM D-150
Elongation400%ASTM D-638
Melt Flow Rate11g/10 minASTM D-3159
Melt Point258°CASTM D-3159
Tensile Strength52MPaASTM D-638
Volume Resistivitymin. 10¹⁷Ω-cmASTM D-257