• One of the BioBlend® XP family of high-performance BioPolymers designed for blown film applications.\n• BioBlend® XP 22250 is a masterbatch that contains 50% NuPlastiQ GP BioPolymer compounded with HDPE.\n• Made from 50% annually renewable agricultural resources.\n• Supplied in pellet form.
Properties
- Physical Form
- Masterbatch
- Solid
Other characteristics
- Brand
- BioBlend® XP
- Carrier
- High-Density Polyethylene (HDPE), Resin-based
- High-Density Polyethylene (HDPE)
- Resin-based
- Density
- 1200.0 - 1200.0 kg/m³
- Functions
- Resin
- Polymer Name
- TPS/HDPE Alloy
- Processing Methods
- Blown Film Extrusion, Extrusion, Film Extrusion
- Compatible Polymers & Resins
- High-Density Polyethylene (HDPE)
- Color
- Opaque
- Tan
- White
- Notes
1) Moisture content was measured with an infrared moisture analyzer at 105°C for 10 minutes. 2) Mechanical properties were measured on injection molded parts made directly from the 50% NuPlastiQ / 50% polyethylene masterbatch. 3) The reported film properties are for a monolayer blown film that was let-down with 50% additional HDPE to a concentration of 25% NuPlastiQ. The thickness was 1.0 mil, and the blow-up ratio was 2.5:1. 4) These values are typical properties only and should not be used for specification purposes. End users should confirm results with their own tests.
- Markets
- Consumer Goods
- Printing & Packaging
- Technology
- Plastics
- Labeling Claims
- Bio-based
- Biodegradable
- Material Features
- Compostable
- High Performance
- High Stiffness
- High Strength
- Low Water Solubility
- Storage and Drying
BioLogiQ BioBlends are dried after production and shipped in sealed moisture-proof bags that are ready to use as supplied. They should be stored indoors in the sealed container away from heat until used.; If pellets are exposed to a humid environment, they will absorb moisture from the air. If needed, dry pellets by introducing warm dry air at no more than 80°C for 1-4 hours.; The estimated moisture content of a BioLogiQ BioBlend can be measured with an infrared moisture analyzer at 105°C for 10 minutes. The result of the measurement will not perfectly equal the moisture content, due to possible partial evaporation of plasticizer. The result from this test should be <0.5% moisture prior to processing.
- Chemical Inventories
- DSL (Canada)
- IECSC (China)
- TSCA (USA)
- Certifications and Compliance
- SARA 311/312
- SARA 313
- Compatible Polymers and Resins
- High-Density Polyethylene (HDPE)
Technical data
Table 1 of 6
4 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Izod - Notched | 15 | J/m | ASTM D256 |
| Tensile Elongation at Break | 9 | % | ASTM D638 |
| Tensile Secant Modulus (at 1%) | 770 | MPa | ASTM D638 |
| Tensile Strength at Break | 25 | MPa | ASTM D638 |
Table 2 of 6
1 row| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Density | 1.2 | g/cm3 | ASTM D792 |
Table 3 of 6
2 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Melting Temperature Range | 126 - 136 | °C | ASTM D3418 |
| Melt Flow Index | 0.9 | g/10 min (190 °C/10 kg) | ASTM D1238 |
Table 4 of 6
1 row| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Moisture Content | max. 0.5 | % | ASTM D6980 |
Table 5 of 6
7 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Dart Drop Test (3) | max. 50 | g | ASTM D1709 |
| Elmendorf Tear MD (3) | max. 10 | g | ASTM D1922 |
| Elmendorf Tear TD (3) | 400 | g | ASTM D1922 |
| Elongation at Break MD (3) | 430 | % | ASTM D882 |
| Elongation at Break TD (3) | max. 5 | % | ASTM D882 |
| Tensile Strength MD (3) | 5400 | psi | ASTM D882 |
| Tensile Strength TD (3) | 2000 | psi | ASTM D882 |
Table 6 of 6
1 row| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Flexural Modulus | 930 | MPa | ASTM D790 |