Nylacast Nylube
- Chemical Family
- Polyamides
Nylacast Nylube contains a combined liquid/solid lubricant system which allows for a coefficient of friction as low as 0.08. This is below that of almost any other polymer available at present. Nylube has substantially improved the wear resistance abilities compared to that of any other currently available lubricated grade of cast nylon, whilst retaining excellent physical property characteristics. Nylube was introduced into the market in 1989 as a logical progression to Nylacast Oilon. Since that time, it has proved to be a supreme wear-resisting grade and one of the most important developments within PA6 materials technology. It is the World Leader for over 30 Years.
Properties
- Physical Form
- Custom, Plates, Rods, Tube
- Custom
- Plates
- Rods
- Tube
Product families
- Consumer Goods — Sports & Recreation
- Exterior & Body
- Interior
- Other Automotive Applications
- Medical Devices & Assemblies
- Other Medical Applications
- Food & Beverage Packaging
- Housings & Enclosures
Other characteristics
- Brand
- Nylacast
- Color
- Red
- Density
- 1141.0 - 1141.0 kg/m³
- Features
Enhanced Physical Properties, Improved Wear, Low Friction, Lubricated
- Polymer Name
- Polyamide 6 (PA 6)
- Tensile Modulus
- 3600.0 - 4000.0 MPa
- Markets
- Automotive & Transportation
- Consumer Goods
- Electrical & Electronics
- Healthcare & Pharma
- Printing & Packaging
- Flame Rating
- IEC 60695-11-10 HB
- Technology
- Plastics
- FDA Compliant
Much like Nylacats Oilon, Nylacast Nylube is suitable for use in applications in the food and pharmaceutical industries as a result of the premium FDA compliant lubricate throughout the material.
- Product Families
- Plastics — Parts, Shapes & Films
- Additives Included
- Lubricant (Unspecified)
- Material Features
- Enhanced Physical Properties
- Improved Wear
- Low Friction
- Lubricated
- Benefits and Features
Excellent Coefficient of Friction - Nylube contains a combined liquid/solid lubricant system which allows for a coefficient of friction as low as 0.08. A figure which is below that of almost any other polymer available at present. Nylube has substantially improved the wear resistance abilities compared to that of any other currently available lubricated grade of cast nylon, whilst retaining excellent physical property characteristics
- Certifications and Compliance
- FDA Compliant
- Plastics and Elastomers End Uses
- Automotive Applications
- Automotive Exterior Parts
- Automotive Interior Parts
- Food Packaging
- Housings
- Medical Devices
- Medical/Healthcare Applications
- Sporting Goods
Technical data
Table 1 of 5
12 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Tensile Strength at Yield (Sample Type 1B, 50mm/min) | 80 - 90 | MPa | ISO 527-1/2;1993 |
| E-modulus (Sample Type 1B, 50mm/min) | 3600 - 4000 | MPa | ISO 527-1/2:1993 |
| Elongation at Break (Sample Type 1B, 50mm/min) | min. 30 | % | ISO 527-1/2:1993 |
| Compressive Strength (Sample Type B, 5mm/min) | 105 - 125 | MPa | ISO 604:2002 |
| Compressive Modulus (Sample Type A, 1mm/min) | 2500 - 2700 | MPa | ISO 604:2002 |
| Flexural Strength (1.5mm/min) | 115 - 125 | MPa | ISO 178:2001 |
| Flexural Modulus (1.5mm/min) | 3350 - 3600 | MPa | ISO 178:2001 |
| Izod Impact Strength (Sample Type A, notched) | 5.5 - 7.0 | kJ/mm² | ISO 180:2000 |
| Dynamic Coefficient of Friction (31.4m/min, 1.75MPa) | 0.075 | — | — |
| Limiting PV | 100.0 | MPa/m | — |
| K-Factor (Wear Factor, 31.4m/min, 1.75MPa) | 3.9x10⁻⁶ | mm³/Nm | — |
| Hardness | 83.0 | Shore D | ISO 868:2003 |
Table 2 of 5
4 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Density (Test Method A) | 1.141 | g/cm³ | ISO 1183:1997 |
| Moisture Absorption (Equilibrium, 50% RH, 23°C) | 2.0 | % | ISO 62:1999(modified) |
| Water Absorption (24 hrs, Immersion at 23°C) | 0.2 | % | ISO 62:1999 (modified) |
| Water Absorption (24 hrs Saturation, Immersion at 23°C) | 5.9 | % | ISO 62:1999 |
Table 3 of 5
7 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Melting Temperature (Tg) | 222.0 | °C | — |
| Glass Transition Temperature | 65.0 | °C | ISO 11359:1999 |
| Heat Deflection Temperature (HDT/A, 1.80MPa) | 75.0 | °C | ISO 75 |
| Maximum/Minimum Continuous Service Temperatures | 110/-40 | °C | — |
| Maximum/Minimum Intermittent Service Temperatures | 180/-100 | °C | — |
| Coefficient of Linear Thermal Expansion (23 - 55°C) | 8x10⁻⁵ | °C⁻¹ | ISO 11359-2:1999 |
| Thermal Conductivity (Mean T = 20°C) | 0.25 | W/m°C | ISO 8301:1991 |
Table 4 of 5
7 rows| Characteristic | Value | Unit | Method |
|---|---|---|---|
| Dielectric Constant (1 Hz) | 3.7 | — | IEC 60250:1969-01 |
| Dielectric Constant (100 Hz) | 4.0 | — | IEC 60250:1969-01 |
| Dissipation Factor (100 Hz) | 0.013 | — | IEC 60250:1969-01 |
| Dielectric Strength | 25.0 | kV/m | IEC 60243:-1:1998-01 |
| Volume Resistivity | min. 1x10¹³ | ohm.m | IEC 60093:1980-01 |
| Surface Resistivity | min. 1x10¹² | ohm.m | IEC 60093:1980-01 |
| Comparative Tracking Index | 600.0 | CTI | IEC 60112:2003-01 |
Table 5 of 5
1 row| Characteristic | Value | Method |
|---|---|---|
| Flammability | HB | IEC 60695-11-10:2003-08 |